2 − Names and Functions of Parts

Rear panel

wDIRECT INPUT jacks

These direct input connectors provide direct line inputs for each channel.

eFOLDBACK output connectors

These output the input signals (INPUT 1 and 2) unchanged.

NOTE

When input is through INPUT 2’s unbalanced RCA pin jacks, the nominal output level is converted to balanced +4 dBu.

rINPUT 2 XLR connectors

These XLR connectors are balanced line inputs for INPUT 2.

(1: GND, 2: HOT, 3: COLD)

tINPUT 2 RCA jacks

These RCA pin jacks are unbalanced line inputs for INPUT 2.

NOTE

oPower connector

Use the included power cord to connect the power source.

CAUTION

When using this unit, always use the included power cord. Moreover, do not use the included power cord with any other equipment. Misuse of a power cord could cause malfunction, fire or electric shock.

pGround lift (GND LIFT) switch

Even when the ground connector is used to ground the unit, this ground connection can be interrupted (ground lift) by setting the GND LIFT switch to the left.

Signals should not be input to both the XLR and the RCA connectors at the same time. Use either the XLR or the RCA connectors for input.

yINPUT 1 XLR connectors

These XLR connectors are balanced line inputs for INPUT 1.

uINPUT 1 TRS jacks

These TRS jacks are balanced line inputs for INPUT 1.

NOTE

Signals should not be input to both the XLR and the TRS connectors at the same time. Use either the XLR or the TRS connectors for input.

iSignal ground (SIGNAL GND) connector

Use a commercially available PVC-covered cord to connect this connector to the signal ground. Note that this is NOT an electrical safety ground (earth).

6 TASCAM MH-8