Models 904/906 To the Installer
050830
Section 1 To the InstallerInstallation
This unit must be installed with the four 4” met al legs
mounted to the base of the unit. These legs are
provided with the oven. Remove the legs from the
packaging found in the oven cavity, and cap them with
the rubber boots (also found in the oven cavity). Mount
the legs into the four holes on the bottom of the unit.
Forpr operbalanc ing, levelt heunit lef t toright and front
to back by adjusting the legs.
This machine is designedfor indoor use only.
Air Clearance
The oven requires a minimum of 1” (25 mm) clearance
around all sides, and 4” (102 mm) clearance on the
bottom to allow for adequate air circulation.
Electrical Connections
This equipment is supplied with a 3-wire cord and
grounding type plug for connection to a single phase,
60 cycle, branch circuit supply. This unit must be
plugged into a properly grounded receptacle. An
appropriate receptacle is supplied with the ov en and is
packaged with the cooking trays.
THESE OVENS ARE NOT FOR HOUSEHOLD USE.
The rated current for the Model 904 is 16 amp.;
therefore the wall outlet must be rated for 20 amps on
adedicated c ircuit. The rated current f or the Model 906
is 15 amp. for 208/60/1 and 12.5 amp. for
220-240/60/1; therefore the wall out let must be rated
for 15 amps on a dedicated circuit. Use the outlet
receptacle provided with the oven.
FOLLOW YOUR LOCAL ELECTRICAL CO DES!
In the United States, this equipment isintended tobe
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70--1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. Compliance therewith and
proper maintenance will result in an installation
essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Stationary appliances which are not equipped with a
power cord and a plug or other device to disconnect
the appliance from the power sourc e must have an
all--poledisconnect ing device with a contact gap of at
least 3 mm installed in the external installation.