2
To the Installer Model632
110407
Air Cooled UnitsDO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76 mm) of
clearance around all sides of the freezer to allow for
adequate air flow across the condensers. A deflector
is provided to prevent recirculation of warm air. Failure
to allow adequate clearance can reduce the
refrigeration capacity of the freezer and possibly
cause permanent damage to the compressor.
Water Connections(Water Cooled Units Only)
An adequate cold water supply must be provided wit h
a hand shut--off valve. On the underside rear of the
base pan, two 1/2” I.P.S. water connections for inlet
and outlet have been provided for easy hook --up. 1/2”
inside diameter water lines should be connected to the
machine. (Flexible lines are recommended, if local
codes permit.) Depending on local water conditions, it
may be advisable to install a water strainer to prevent
foreign substances from clogging the automatic water
valve. There will be only one water “in” and one water
“out” connection for both single--head and
double--head units. DO NOT install a hand shut--off
valve on the water “out” line! Water should always flow
in this order: first, through the aut omatic water valve;
second, through the condenser; and third, through t he
outlet fitting to an opentrapdrain.
A back flow prevention devi ce isreq uired
on the incoming water connectio n side. Please
refer to the applicable National, State, and local codes
for determining the proper configuration.
Electrical ConnectionsIn the United States, this equipment isintended tobe
installed in accordance with the National Electrical
Code(NEC), A NSI/NFPA70-1987. T hepur pose of the
NEC code is the practical safeguarding of persons and
property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. In all other areas of the world,
equipment should be installed in accordance with the
existing local codes. Please contact your local
authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each unit requires one power supply for each data
labelon t he unit. Check the data label(s) on the freezer
for branch circuit overcurrent protection or fuse, c ircuit
ampacity and other electrical specific ations. Refer to
thewiring diagr am provided inside of the electrical box,
for proper power connections.
CAUTION: THIS EQUIPMENT M UST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
oft he frame by the authorized installer. The inst allation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s frame.