42 Models C708 & C716Operating Procedures
Brush Cleaning
Step 1
Prepare two gallons (7.6 liters) of an approved 100
PPM cleaning/sanitizing solution (example: Kay-5r).
USE WARM WATER AND FOLLOW THE
MANUFACTURER’SSPECIF ICATIONS. Make sure
all brushes provided with the freezer are available
for brush cleaning.
Step 2
Thoroughly brush clean all disassembled parts in the
cleaning solution, making sure all lubricant and mix
film is removed. Be sure to brush all surfaces and
holes, especially the holes in the pump components
and the draw valve hole in the freezer door.
Rinse all parts with clean, warm water. Place the
parts on a clean, dry surface to air dry overnight.
Step 3
Return to the freezer with a small amount of
cleaning solution. Using the black brush, clean the
rear shell bearing at the back of the freezing
cylinder. (See Figure 60.)