Models RD30/RC25 Operating Procedures
081029
Step 2
Dispenser. Prepare a pail of approved 100 PPM
sanitizing solution (examples: 2--1/2 gal. [9.5 liters] of
Kay--5Ror2 gal. [7.6 liters] of Ster a--SheenR).USE
WARMWATER AND FOLLOW THEMANUFACTUR-
ER’S SPECIFICATIONS. Remove the upper rear
cover, and open the hopper cover. Pour the sanitizing
solution into the hopper and allow the solution to flow
into the freezing cylinder.
Figure 30
Step 3
Once the mix float switch is submerged in the
sanitizing solution, brush clean the mix hopper, mix
inlet hole, and mix level float switch.
Figure 31
Step 4
Place the control switch in the “WASH” position. This
will cause the sanitizing solution in the freezing
cylinder to be agitated. Allow the solution to agitat e for
five minutes.
Figure 32
Step 5
Placet he control switch in the “OFF” posit ion. Place an
empty mix pail beneath the door spout . Open the draw
valve and draw off all of the sanitizing soluti on. When
the sanitizer stops flowing from the door s pout, close
the draw valve.
Figure 33
Step 6
Replace the hopper cover and the upper rear cover.
Figure 34