S

S

S

S

Cleaning and sanitizing schedules are

governed by your state or local regulatory agencies

and must be followed accordingly. Please refer to the

cleaning section of this manual for the proper

procedure to clean this unit.

DO NOT allow untrained personnel to operate

this unit.

DO NOT put objects or fingers in door spout.

DO NOT operate the freezer unless all service

panels and access doors are restrained with

screws.

DO NOT remove the freezer door or beater

assembly unless the control switches are in

the “OFF” position.

This unit is designed to maintain product

temperature under 41_F (5_C). Any product being

added to this unit must be below 41_F (5_C). Failure

to follow this instruction may result in health hazards

and poor freezer performance.

Failure to follow these instructions may result in severe

personal injury from hazardous moving parts.

DO NOT obstruct air intake and discharge openings:

S

This unit has many sharp edges that can

cause severe injuries.

S

S

DO NOT put objects or fingers in the door

spout. This may contaminate the product and

cause severe personal injury from blade

contact.

USE EXTREME CAUTION when removing

the beater asssembly. The scraper blades are

very sharp.

S

S

150 and 152: Minimum of 6” (152 mm) of

clearance around both sides. Install the skirt

provided on the right side of the unit and place

the back of the unit against a wall to prevent

recirculation of warm air.

162: Minimum of 6” (152 mm) on all sides.

Install the skirt provided on the rear of the unit.

168: Minimum of 3” (76 mm) on all sides.

Install the skirt provided on the rear of the unit.

For Indoor Use Only: This unit is designed to operate

indoors, under normal ambient temperatures of

70_-75_F (21_-24_C). The unit has successfully

performed in high ambient temperatures of

104_(40_C) at reduced capacities.

This freezer must be placed on a level

surface. Failure to comply may result in personal injury

or equipment damage.

DO NOT run the unit without product. Failure to follow

this instruction can result in damage to the unit.

Access to the service area of the unit is

restricted to persons having knowledge and practical

experience with the appliance, in particular as far as

safety and hygiene are concerned.

NOISE LEVEL: Airborne noise emission does not

exceed 78 dB(A) when measured at a distance of 1.0

meter from the surface of the unit and at a height of 1.6

meters from the floor.

130722

Safety

6

Models 150, 152, 162, 168

Page 10
Image 10
Open full-size image