3

Models 150, 152, 162, 168

To the Installer

130809

S

Stationary appliances which are not equipped

with a power cord and a plug or another device

to disconnect the appliance from the power

source must have an all-pole disconnecting

device with a contact gap of at least 3 mm

installed in the external installation.

S

Appliances that are permanently connected to

fixed wiring and for which leakage currents

may exceed 10 mA, particularly when

disconnected, not used for long periods, or

during initial installation, shall have protective

devices such as a GFI to protect against the

leakage of current, installed by authorized

personnel to the local codes.

S

Supply cords used with this unit shall be

oil-resistant, sheathed flexible cable, not

lighter than ordinary polychloroprene or other

equivalent synthetic elastomer-sheathed cord

(Code designation 60245 IEC 57) installed

with the proper cord anchorage to relieve

conductors from strain, including twisting, at

the terminals and protect the insulation of the

conductors from abrasion.

If the supply cord is damaged, it must be

replaced by the manufacturer, its service

agent, or similarly qualified person, in order to

avoid a hazard.

Beater Rotation

Beater rotation must be clockwise as viewed

looking into the freezing cylinder.

Note: The following procedures should be

performed by an authorized service technician.

To correct rotation on a three- phase unit, interchange

any two incoming power supply lines at freezer main

terminal block only. To correct rotation on a

single- phase unit, change the leads inside the beater

motor. (Follow diagram printed on motor.)

Electrical connections are made directly to the

terminal block provided in the splice box, mounted on

the base pan on each side of the model 168, and

located in the splice boxes mounted mid- level on the

frame channel on the sides of the model 162.

Refrigerant

In consideration of our environment, Taylor

uses only earth friendly HFC refrigerants. The HFC

refrigerant used in this unit is R404A. This refrigerant

is generally considered non-toxic and non-flammable,

with an Ozone Depleting Potential (ODP) of zero (0).

However, any gas under pressure is potentially

hazardous and must be handled with caution.

NEVER fill any refrigerant cylinder completely with

liquid. Filling the cylinder to approximately 80% will

allow for normal expansion.

Use only R404A refrigerant that conforms to

the AHRI standard 700 specification. The use of any

other refrigerant may expose users and operators to

unexpected safety hazards.

Refrigerant liquid sprayed onto the skin may

cause serious damage to tissue. Keep eyes and skin

protected. If refrigerant burns should occur, flush

immediately with cold water. If burns are severe, apply

ice packs and contact a physician immediately.

Taylor reminds technicians to be cautious of

government laws regarding refrigerant recovery,

recycling, and reclaiming systems. If you have any

questions regarding these laws, please contact the

factory Service Department.

WARNING: R404A refrigerant used in

conjunction with polyolester oils is extremely moisture

absorbent. When opening a refrigeration system, the

maximum time the system is open must not exceed 15

minutes. Cap all open tubing to prevent humid air or

water from being absorbed by the oil.