3
Models 150, 152, 162, 168 Tothe Instal ler
130809
SStationary appliances which are not equipped
witha power cord and a plug or another dev ice
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 3 mm
installed in the external installation.
SAppliancest hat are permanently connected t o
fixed wiring and for which leakage currents
may exceed 10 mA, particularly when
disconnected, not used for long periods, or
during initial installation, shall have protective
devices such as a GFI to protect against t he
leakage of current, installed by authorized
personnel to the local codes.
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable, not
lighter than ordinary polychloroprene or other
equivalent synthetic elastomer-sheat hed cord
(Code designation 60245 IEC 57) installed
with the proper cord anchorage to relieve
conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent, or similarly qualified person, in order to
avoid a hazard.
Beater Rotation
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: The following procedures should be
performed by an authorized service technici an.
Tocorrect rot ation on a three- phase unit, interchange
any two incoming power supply lines at freezer main
terminal block only. To correct rotation on a
single- phase unit, change the leads inside the beater
motor. (Follow diagram printed on motor.)
Electrical connections are made directly to the
terminal block provided in the splice box, mounted on
the base pan on each side of the model 168, and
located in the splice boxes mounted m id-level on t he
frame channel on the sides of the model 162.
Refrigerant
In consideration of our environment, Taylor
uses only earth friendly HFC refrigerant s. The HFC
refrigerant used in this unit is R404A. This refrigerant
is generally considered non-toxic and non-flammable,
with an Ozone Depleting Potential (ODP) of zero ( 0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Use only R404A refrigerant that conforms to
the AHRI standard 700 specification. The use of any
other refrigerant may expose users and operat ors to
unexpected safety hazards.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe, apply
ice packs and contact a physician immediately.
Taylor reminds technicians to be cautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory Service Department.
WARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely moist ure
absorbent. When opening a refrigeration system, the
maximumt ime the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.