22

Models 150, 152, 162, 168

Operating Procedures

Note:

Models 162/168 have three draw handles.

Slide the tip of the draw handle into the slot of the draw

valve, starting from the right. Slide the short pivot pin

through the far right draw handle. Slide the long pivot

pin through the far left and middle draw handles.

Figure 27

Step 13

Snap the design cap(s) over the bottom of the freezer

door spout(s).

Figure 28

Step 14

Lay the feed tube(s) in the bottom of the mix hopper(s).

Sanitizing

Step 1

Prepare an approved 100 PPM sanitizing solution (ex-

amples: Kay- 5

R

or Stera- Sheen

R

). USE WARM

WATER AND FOLLOW THE MANUFACTURER’S

SPECIFICATIONS.

Step 2

Pour one gallon (3.8 liters) of the sanitizing solution

into the hopper and allow it to flow into the freezing

cylinder.

Step 3

While the solution is flowing into the freezing cylinder,

brush- clean the mix hopper, mix level float stem, mix

level float, mix inlet hole, and feed tube.

Figure 29

Figure 30

Page 26
Image 26
Open full-size image