Absolute Maximum Ratings:

 

 

 

 

Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device.

 

Characteristic

Min

Max

Unit

Notes & Conditions

Continuous Input Voltage

-0.5

80

Vdc

 

Transient Input Voltage

---

100

Vdc

100mS max.

 

 

 

 

 

Isolation Voltage

---

1500

Vdc

 

 

 

 

 

 

Storage Temperature

-55

125

˚C

 

 

 

 

 

 

 

 

 

 

Measured at the location specified in the thermal

 

 

 

 

 

 

 

 

measurement figure. Maximum temperature varies

Operating Temperature Range (Tc)

-40

125

˚C

with model number, output current, and module

 

 

 

 

orientation – see curve in thermal performance

 

 

 

 

section of the data sheet.

 

 

 

 

 

Input Characteristics:

Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.

Characteristic

Min

Typ

Max

Unit

Notes & Conditions

Operating Input Voltage

36

48

75

Vdc

 

Maximum Input Current

---

---

4

A

Vin = 0 to Vin,max

 

 

 

 

 

 

Turn-on Voltage

---

33

---

Vdc

 

 

 

 

 

 

 

Turn-off Voltage

26

30

---

Vdc

 

 

 

 

 

 

 

Hysteresis

0.5

3

---

Vdc

 

 

 

 

 

 

 

Startup Delay Time from application of input

---

35

---

mS

Vo = 0 to 0.1*Vo,nom; on/off =on,

voltage

 

 

 

 

Io=Io,max, Tc=25˚C

 

 

 

 

 

 

Startup Delay Time from on/off

---

35

---

mS

Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom,

 

 

 

 

 

Io=Io,max,Tc=25˚C

 

 

 

 

 

 

Output Voltage Rise Time

---

50

---

mS

Io=Io,max,Tc=25˚C, Vo=0.1 to 0.9*Vo,nom

 

 

 

 

 

 

Inrush Transient

---

---

0.2

A2s

 

 

 

 

 

 

 

Input Reflected Ripple

---

15

---

mApp

See input/output ripple and noise

 

 

 

 

 

measurements figure; BW = 20 MHz

 

 

 

 

 

 

Input Ripple Rejection

---

55

---

dB

@120Hz

 

 

 

 

 

 

Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 10A is required, see the Safety Considerations section of the data sheet.

©2004 TDK Innoveta® Inc.

 

￿ (877) 498-0099

iEAFullDatasheet 032707 3/29/2007

Revision 2.0

4/41

 

 

 

 

Page 4
Image 4
TDK iEA Series manual Input Characteristics, Characteristic Min Max Unit