Data Sheet: Belleta® iEA Series –Single Output Eighth Brick

Input/Output Ripple and Noise Measurements:

Battery

2 1

12uH

1 2

220uF

esr<0.1

100KHz

2 1

 

+

33uF

Vinput

esr<0.7

 

100KHz

-

 

 

+

 

1

1

 

 

RLoad

 

 

 

 

Cext

Voutput

 

 

 

2

 

 

 

2

-

 

 

Ground Plane

The input reflected ripple is measured with a current probe and oscilloscope. The ripple current is the current through the 12uH inductor.

The output ripple measurement is made approximately 9 cm (3.5 in.) from the power module using an oscilloscope and BNC socket. The capacitor Cext is located about 5 cm (2 in.) from the power module; its value varies from code to code and is found on the electrical data page for the power module of interest under the ripple & noise voltage specification in the Notes & Conditions column.

Safety Considerations:

For safety agency approval of the system in which the DC-DC power module is installed, the power module must be installed in compliance with the creepage and clearance requirements of the safety agency. The isolation is basic insulation. For applications requiring basic insulation, care must be taken to maintain minimum creepage and clearance distances when routing traces near the power module.

As part of the production process, the power modules are hi-pot tested from primary and secondary at a test voltage of 1500Vdc.

To preserve maximum flexibility, the power modules are not internally fused. An external input line normal blow fuse with a maximum value of 10A is required by safety agencies. A lower value fuse can be selected based upon the maximum dc input current and maximum inrush energy of the power module.

When the supply to the DC-DC converter is less than 60Vdc, the power module meets all of the requirements for SELV. If the input voltage is a hazardous voltage that exceeds 60Vdc, the output can be considered SELV only if the following conditions are met:

1)The input source is isolated from the ac mains by reinforced insulation.

2)The input terminal pins are not accessible.

3)One pole of the input and one pole of the output are grounded or both are kept floating.

4)Single fault testing is performed on the end system to ensure that under a single fault, hazardous voltages do not appear at the module output.

Warranty:

TDK Innoveta’s comprehensive line of power solutions includes efficient, high- density DC-DC converters. TDK Innoveta offers a three-year limited warranty. Complete warranty information is listed on our web site or is available upon request from TDK Innoveta.

©2004 TDK Innoveta® Inc.

 

￿ (877) 498-0099