Advance Data Sheet: MaxetaTM iFA Series

Absolute Maximum Ratings:

Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device.

Characteristic

Min

Max

Unit

Notes & Conditions

Continuous Input Voltage

-0.5

40

Vdc

 

Transient Input Voltage

---

50

Vdc

100mS max.

 

 

 

 

 

Isolation Voltage

 

 

 

 

Input to Output

---

1500

Vdc

Basic Insulation

Input to Base-plate

---

1500

Vdc

Basic Insulation

Output to Base-plate

---

500

Vdc

Operational Insulation

 

 

 

 

 

Storage Temperature

-55

125

˚C

 

 

 

 

 

 

 

 

 

 

Measured at the location specified in the thermal

Operating Temperature Range (Tc)

-40

115*

˚C

measurement figure; maximum temperature varies with

output current and module orientation – see curve in the

 

 

 

 

 

 

 

 

thermal performance section of the data sheet.

 

 

 

 

 

Input Characteristics:

Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.

Characteristic

Min

Typ

Max

Unit

Notes & Conditions

 

 

24

 

 

When 18V ≤ Vin < 19V, the modules will

Operating Input Voltage

19

36

Vdc

continue to operate, but the output

(28) #

voltage regulation may be out of spec at

 

 

 

 

 

full load condition

 

 

 

 

 

 

Input Current

---

28.2

37

A

Vin = 0 to Vin,max

 

 

 

 

 

 

Input Low End Turn-on Voltage

---

17.9

19

Vdc

 

 

 

 

 

 

 

Input Low End Turn-off Voltage

---

16.1

19

Vdc

 

 

 

 

 

 

 

Hysteresis

---

1.8

---

Vdc

 

 

 

 

 

 

 

Input Over-voltage Turn-off Voltage

---

38.6

---

Vdc

 

 

 

 

 

 

 

Input High End Turn-on Voltage

36

37.6

---

Vdc

 

 

 

 

 

 

 

Startup Delay Time from application of input voltage

---

10

---

mS

Vo = 0 to 0.1*Vo,nom; on/off =on,

Io=Io,max, Tc=25˚C

 

 

 

 

 

 

 

 

 

 

 

Startup Delay Time from on/off

---

8

---

mS

Vin = Vin,nom, Io=Io,max, Tc=25˚C

 

 

 

 

 

 

Output Voltage Rise Time

---

42

60*

mS

Io=Io,max, Vo=0.1 to 0.9*Vo,nom,

Tc=25˚C

 

 

 

 

 

 

 

 

 

 

 

Inrush Transient

---

---

1*

A2 S

 

 

 

 

 

 

 

 

 

 

 

 

Vin=Vin,nom, Io=Io,max (0 to 20MHz)

Input Reflected Ripple

---

5

---

mApp

See input/output ripple measurement

 

 

 

 

 

figure; BW = 5 MHz

 

 

 

 

 

 

Input Ripple Rejection

---

41

---

dB

@120Hz

 

 

 

 

 

 

* Engineering Estimate

#Telecom 24V battery plant voltage is typically set at 27.24V

Caution: The power modules are not internally fused. An external input line fuse with a maximum value of 40A is required. See the Safety Considerations section of the data sheet.

©2005 TDK Innoveta Inc.

 

￿ (877) 498-0099

iFA Advance Datasheet

6/6/2005

5/18

 

Page 5
Image 5
TDK iFA Series manual Absolute Maximum Ratings, Input Characteristics