Data Sheet: PoweretaTM iQP Series –Single Output Quarter Brick
©2006 TDK Innoveta Inc.
iQP 3.3V/70A Datasheet 8/3/2006
(
877
)
498-0099 4/15
Absolute Maximum Ratings:
Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device.
Input Characteristics:
Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.
Characteristic Min Typ Max Unit Notes & Conditions
Operating Input Voltage 36 48 75 Vdc
70A output --- --- 8 A Vin = 0 to Vin,max, Io=Io,max, Vo=Vo,nom Maximum Input Current
Turn-on Voltage --- 34.4 --- Vdc
Turn-off Voltage --- 32.3 --- Vdc
Hysteresis --- 2.1 --- Vdc
Startup Delay Time from application of input
voltage
--- 4 --- mS Vo = 0 to 0.1*Vo,nom; on/off =on,
Io=Io,max, Tc=25˚C
Startup Delay Time from on/off --- 3 --- mS Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom,
Io=Io,max,Tc=25˚C
Output Voltage Rise Time --- 25 --- mS Io=Io,max,Tc=25˚C, Vo=0.1 to 0.9*Vo,nom
Inrush Transient --- 0.03 0.05 A2s Exclude external input capacitors
Input Reflected Ripple --- 6 --- mApp See input/output ripple and noise
measurements figure; BW = 20 MHz
Input Ripple Rejection --- 65 --- dB @120Hz
* Engineering Estimate
Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 15A is required; see the
Safety Considerations section of the data sheet.
Characteristic Min Max Unit Notes & Conditions
Continuous Input Voltage -0.5 80 Vdc
Transient Input Voltage --- 100 Vdc 100mS max.
Isolation Voltage
Input to Output
Input to Base-plate
Output to Base-plate
---
---
---
1500
1500
500
Vdc
Vdc
Vdc
Basic Insulation
Basic Insulation
Operational Insulation
Storage Temperature -55 125 ˚C
Operating Temperature Range (Tc)
-40 119 ˚C
Measured at the location specified in the thermal
measurement figure. Maximum temperature varies
with model number, output current, and module
orientation – see curve in thermal performance
section of the data sheet.