DA-88 quick ref.doc

 

 

10/14/97

7:27 PM

 

Basic Functions cont.

Software Version 4.01

￿Items marked SY are only available when the SY-88 is installed.

 

Function

Display

 

To Enter Function

To Enter

Remarks

 

 

 

 

LED

 

 

Data

 

 

 

17

Slave reference, Time Code or ABS

ABS

SY

Press ￿ & ￿

￿ or ￿

Press DISPLAY to exit

 

 

 

time

 

 

 

 

 

 

 

18

Digital or Analog output mode

 

 

Hold ￿ press Digital In

-

This sets a 43Fs delay on all 8 tracks for digital

 

selection

 

 

 

 

dubbing. Display will exit automatically

 

 

19

Track Delay

 

 

Hold ￿ press DISPLAY

￿ or ￿

Press Track Assign to select track to delay. Press

 

 

 

 

 

 

DISPLAY to exit

 

 

20

ALL Track Delay

 

 

Hold ￿ press DISPLAY

￿ or ￿

If no change is made, individual track delay values

 

 

 

 

then Hold Rec. for track 1

 

are retained.

 

 

 

 

 

 

& press Rec. for track 2

 

Press DISPLAY to exit

 

 

21

Crossfade

 

 

Hold ￿ press DISPLAY

￿ or ￿

Press DISPLAY to exit

 

 

22

Shuttle Monitor Mode

 

 

Hold ￿ press SHUTTLE

￿ or ￿

When ON this will mute all tracks not in Rec Ready

 

 

 

 

 

 

when in shuttle mode. Rec Ready tracks will switch

 

 

 

 

 

 

to Input. Press DISPLAY to exit

 

 

23

OFFSET Tally, On / Off

 

 

Hold ￿ press CHASE

￿ or ￿

Press DISPLAY to exit

 

 

24

Punch In point Display & Modify

MEMO 1

 

Perform Rehearsal

￿ or ￿

Press DISPLAY + ￿ to Exit or DISPLAY to go to

 

 

 

 

 

 

Punch out point

 

 

25

Punch Out point Display & Modify

MEMO 2

 

Perform Rehearsal

￿ or ￿

Press DISPLAY + ￿ to Exit

 

 

26

Display Preroll and Enter or modify

ABS

 

Press ￿ & ￿ when

￿ or ￿

Press DISPLAY + ￿ to Exit

 

 

 

data

 

 

Rehearsal or Auto In LED

 

 

 

 

 

 

 

 

is blinking or On

 

 

 

 

27

Greeting

ABS

 

In TEST mode Hold ￿+ ￿

￿ or ￿

Use ￿ or ￿ to scroll through letters. Press

 

 

 

 

 

 

+ DISPLAY + and press

and

￿

 

￿

 

 

 

 

remote. Release ￿& ￿

DISPLAY

whenDISPLAYdoneafterto Exiteachmessagecorrect letter.mode. PressReboot.

&

 

 

 

 

 

first then DISPLAY

 

 

 

 

28

Display Errors

Any

 

Press REMOTE button

-

Track Meters 1 & 2 show Block Error Rate in real

 

 

 

 

when in TEST mode

 

time for playback heads A & B

 

 

29

Enter SY-88 Menu System

TC

SY

Press ￿ & ￿

-

This enters the SY-88 Menu system

 

 

30

Exit SY-88 Menu System

SY

Hold DISPLAY press ￿

-

This will exit SY-88 Menu system

 

 

31

Chase Record Enable

ABS

 

Hold ￿ press TC Rec

￿ or ￿

Allows front panel Record command on slave units.

 

 

 

 

button

 

Must have SYS version.34.02

 

 

32

20dB or 16dB Headroom Select

ABS

 

Hold press ALL INPUT

￿ or ￿

Requires Modification & SYS ver 61.03

 

 

Page 2

© TEAC America, Inc., 1997 All rights reserved.

Page 2
Image 2
Teac DA-88 manual Basic Functions Software Version, Memo