Safety Summary

Cautions and Warnings

This informaton is intended as a guide for trained and qualified personnel who are aware of the dangers involved in handling potentially hazardous electrical/electronic equipment. It is not intended to contain a complete list of all safety precautions which should be observed by personnel in using this or other electronic equipment.

The installation, maintenance and service of this equipment involves risks both to personnel and equipment and must be performed only by qualified personnel exercising due care.

Personnel engaged in the installation, operation, maintenance or servicing of this equipment are urged to become familiar with First Aid theory and practises.

During installation and operation of this equipment, local building safety and fire protection standards must be observed.

Before connecting the equipment to the power supply of the installation, the proper functioning of the protective earth lead of the installation needs to be verified.

Whenever it is likely that safe operation is impaired, the apparatus must be made inoperative and secured against any unintended operation. The appropriate servicing authority must then be informed. For example, safety is likely to be impaired if the apparatus fails to perform the intended function or shows visible damage.

This product has been designed and tested according to EN60065.

When performing service, be sure to read and comply with the warning and caution notices appearing in the manuals. Warnings indicate danger that requires correct procedures or practices to prevent death or injury to personnel. Cautions indicate procedures or practices that should be followed to prevent damage or destruction to equipment or property.

WARNING

THE CURRENT AND VOLTAGES PRESENT IN THIS EQUIPMENT ARE DANGEROUS. ALL PERSONNEL MUST AT ALL TIMES FOLLOW THE SAFETY REGULATIONS.

ALWAYS DISCONNECT POWER BEFORE REMOVING

COVERS OR PANELS.

ALWAYS DISCHARGE HIGH VOLTAGE POINTS

BEFORE SERVICING.

NEVER MAKE INTERNAL ADJUSTMENTS, PERFORM MAINTENANCE OR SERVICE WHEN ALONE OR WHEN FATIGUED.

IN CASE OF AN EMERGENCY ENSURE THAT THE

POWER IS DISCONNECTED.

ANY INTERRUPTION OF THE PROTECTION

CONDUCTOR INSIDE OR OUTSIDE THE APPARATUS, OR DISCONNECTION OF THE PROTECTIVE EARTH TERMINAL, IS LIKELY TO MAKE THE APPARATUS DANGEROUS. INTENTIONAL INTERRUPTION IS PROHIBITED.

FOR SAFETY REASONS THE CPU MUST BE MOUNTED

IN A 19-inch RACK WHICH HAS SAFETY COVERS

ACCORDING TO IEC65.

WHEN TWO CPUs ARE MOUNTED ABOVE EACH OTHER THE MINIMUM DISTANCE BETWEEN THEM MUST BE 50MM OR THE RACK MUST BE FORCE-AIR COOLED.

USE ONLY FUSES OF THE TYPE AND RATING

SPECIFIED.

CAUTION

To prevent risk of overheating, ventilate the product

correctly.

Connect the product only to a power source with the

specified voltage rating.

Only connect a Triax cable from the LDK 6 camera family to an LDK 6 CPU. Never connect it to any other base station.

Never connect the Triax cable from a camera to a CPU of a different family; never connect the LDK family to the TTV family.

Do not allow system ground currents to exceed 1.5A in the outer shield of the triax cable or 0.2A in other cable shields.

It is strickly prohibited to short circuit the inner and outer shields of a triax cable used to connect a camera to a base station.

1-2

User's Guide LDK 4502 - HDTV Camera Base Station

Safety Instructions

Page 6
Image 6
Technicolor - Thomson LDK 4502 manual Safety Summary, According to IEC65

LDK 4502 specifications

The Technicolor Thomson LDK 4502 is a prominent figure in the world of professional broadcast cameras, designed specifically to meet the demanding needs of high-definition video production. Renowned for its exceptional image quality and versatile capabilities, the LDK 4502 is utilized widely in live broadcasting, sports events, and studio environments.

One of the most notable features of the LDK 4502 is its capability to capture high-definition images at resolutions up to 1080p. This ensures that broadcasters can deliver crisp and clear visuals that meet modern audience expectations. The camera is equipped with a 2/3-inch CCD sensor, providing excellent sensitivity and a wide dynamic range. This characteristic is crucial for capturing detailed images even in low-light conditions, making the LDK 4502 a reliable tool for varied shooting environments.

The LDK 4502 incorporates a digital signal processing engine that aids in optimizing image quality. It features advanced noise reduction technology, ensuring that the video footage is clean and free from unwanted artifacts, even in challenging shooting conditions. This level of image processing maintains the integrity of the visuals, catering to the high standards of professional broadcasts.

In addition to its image capture capabilities, the LDK 4502 is designed with usability in mind. The camera features an ergonomic design that provides ease of operation for camera operators, allowing for seamless adjustments to settings, focus, and zoom. The camera's modular design also facilitates integration with various accessories and broadcast equipment, enhancing its adaptability in different production scenarios.

Another significant characteristic of the LDK 4502 is its support for multiple output formats. It can serve various connectivity options, including HD-SDI and optical fiber, which are essential for live broadcasting scenarios that require low-latency transmissions. This versatility ensures that the camera can seamlessly integrate into existing broadcast infrastructures.

Overall, the Technicolor Thomson LDK 4502 camera is a robust and feature-rich solution for high-definition video production. With its exceptional imaging capabilities, advanced technologies, and user-friendly design, it stands out as a preferred choice for professional broadcasters around the globe. Its ability to deliver stunning visuals while providing operational flexibility makes it an essential tool for any serious production team.