Teka EM/60 3G 1P AI AL TR (FUND), EM/60 3G 1P AI TR TV Connecting the electricity, Gas conversion

Models: EM/60 4G AI AL TR (FUND) EM/60 3G 1P AI AL TR (FUND) EM/60 3G 1P AI AL TR TV (FUND) EM/60 3G 1P AI TR TV (FUND) EM/60 4G AI AL TR TV EM/60 4G AI AL TR TV (FUND) EM/60 3G 1P AI TR TV EM/60 3G 1P AI TR (FUND) EM/60 4G AI TR EM/60 4G AI TR (FUND) EM/60 3G 1P AI AL TR TV

1 19
Download 19 pages 2.31 Kb
Page 9
Image 9

adjusted. To do this, light the burners and check that they do not go out if you switch quickly from the maximum to the minimum.

Connecting the electricity

Before connecting the hob to the electric mains, check that the voltage and fre- quency of themains matches that shown on the hob s rating plate, which is located lower down, and on the guarantee certifi- cate or, where appropriate, the technical datasheet supplied, which should be kept together with this manual.

The connection is made via an omnipolar switch or plug where accessible, which is suitable for the intensity to be tolerated and which has a minimum gap of 3 mm between its contacts, which will ensure disconnection in case of emergency or when cleaning the hob.

The connection should include correct ear- thing, in compliance with current norms.

If the flexible supply cable fitted to these appliances ever needs to bechanged, it should be replaced by TEKA s official SAT cable, which requires special tools.

The input cable should not be in contact either with the body of the hob or with the body of the oven, if the oven is installed in the same unit.

GB

Gas conversion

Important!

Any alteration that is to be made to the appliance to convert it to a different type of gas should only be carried out by an authorised person and should comply with current standards.

tance:Information for Technical Assis-

wheneverthe type of gas or the appliance s pressure is changed, the new regulation plate should be placed on top of the old one so that the new features can be seen after the change.

The tasks involved in conversion are:

*Replace the injectors.

*Adjust the taps minimums.

The injectors required for each gas type are shown in table 1.

To replace the injectors, follow these ins- tructions:

1Remove the grids and upper parts of the burner so that the injector can be seen.

2Using a number 7 pipe spanner, remove the injectors and replace them with the new ones. Ensure that the injector is properly tightened and so avoid gas escaping.

3Replace the grid and burners that were previously removed.

Whenadjust thethe injectorsminimumshave been changed, as follows:

1Turn the burners on to their minimum.