Teka EX/70 5G AI AL TR FUND, EX/60 4G AI FUND manual Electrical Connection

Models: EX/60 4G AI FUND EX/70 5G AI AL TR FUND

1 15
Download 15 pages 14.26 Kb
Page 8
Image 8

INSTALLATION

8) ELECTRICAL CONNECTION

The electrical connections of the appliance must be carried out in compliance with the provisions and standards in force.

Before connecting the appliance, check that:

-The electrical capacity of the mains supply and current sockets suit the maximum power rating of the appliance (consult the data label applied to the underside of the hot plate).

-The socket or system has an efficient earth connection in compliance with the provisions and standards in force. The manufacturer declines all responsibility for failing to comply with these provisions.

When the appliance is connected to the electricity main by a socket:

-Fit a standard plug suited to the load indicated on the data label to the cable.

-Fit the wires following figure 11, taking care of respecting the following correspondences:

Letter L (live) = brown wire; Letter N (neutral) = blue wire;

Earth symbol = green - yellow wire

-The power supply cable must be positioned so that no part of it is able to reach an overtemperature of 75 K.

-Never use reductions, adapters of shunts for connection since these could create false contacts and lead to dangerous overheating.

When the appliance is connected straight to the electricity main:

-Install an omnipolar circuit-breaker between the appliance and the electricity main. This circuit- breaker should be sized according to the load rating of the appliance and possess a minimum 3 mm gap between its contacts.

-Remember that the earth wire must not be interrupted by the circuit-breaker.

-Alternatively, the electrical connection may also be protected by a high sensitivity differential circuit- breaker.

You are strongly advised to fix the relative yellow- green earth wire to an efficient earthing system.

WARNINGS:

The installer should bear in mind that the mixed appliance is the Y type. The rear wall, adjacent and surrounding surfaces must therefore be able to withstand an overtemperature of 75 K.

All our appliances are designed and manufactured in compliance with European standards EN 60 335-1 and EN 60 335-2-6 plus the relative amendments.

The appliance complies with the provisions of the following EEC Directives:

-89/336 + 92/31 + 93/68 regarding to electromagnetic compatibility.

-73/23 + 93/68 regarding electrical safety.

FIG. 11

8

Page 8
Image 8