EDIT Menu

Figure 3 "79: Gray Code Pattern Display

Example of Waveform Data Creation. In the following operation, you will replace the data between the vertical bar cursors with a Count Up pattern, with the waveform point size set to 4096.

1.Select Standard Waveform from the bottom menu.

2.Press the CURSOR button on the front panel. Using the general purpose knob, move the left and right vertical bar cursors all the way to the left and right, respectively, so the entire editing area is selected.

3.Select Pattern from the side menu, then select Count Up by turning the general purpose knob or pressing the Pattern button in the side menu.

4.Select Step from the side menu. Using the numeric keys or the general purpose knob, set the step to 1.

5.Select Max from the side menu. Using the numeric keys or the general purpose knob, set the end point for the Count Up pattern to 4095.

6.Select Min from the side menu. Using the numeric keys or the general purpose knob, set the starting point for the Count Up pattern to 0.

7.Select Execute from the side menu.

The data between the vertical bar cursors will be replaced by the Count Up pattern that you have designated. Figure 3 -78 shows the Count Up pattern created with the values used in this example.

AWG2021 User Manual

3 "103