EDIT Menu

Editing in the Frequency Domain

(7)Left vertical bar cursor The left cursor indicates the left starting point for editing. The active cursor will be brightly highlighted with dot lines.

(8)Right vertical bar cursor Indicates the right end point for editing.

(9) Button Operations

This area shows how the front panel buttons operate in this

 

menu.

 

Pressing the CURSOR button toggles the active vertical bar

 

cursor.

 

Pressing the VALUE or ENTER button puts the system into a

 

mode in which the magnitude at the frequency of the active

 

vertical bar cursor can be changed.

 

Pressing the VALUE or ENTER button puts the system into a

 

mode in which the phase at the frequency of the active vertical

 

bar cursor can be changed.

 

When Draw... has been selected, pressing the CURSOR

 

button moves the active vertical bar cursor.

 

When Draw... has been selected, pressing the VALUE or

 

ENTER button moves the point cursor.

 

When Draw... has been selected, pressing VALUE or ENTER

 

toggles the direction in which the point cursor moves from

 

vertical to horizontal or vice￿versa.

Select Operation from the bottom menu to change the signal magnitude and phase in the frequency domain. The following items will appear in the side menu:

Right peak

Left peak

Draw...

Editing Magnitude. Here is the procedure for editing the magnitudes.

1.Select Operation from the bottom menu.

2.Press the CURSOR button on the front panel to select the left/right vertical bar cursor. Using the numeric keys or the general purpose knob, move the active vertical bar cursor to the frequency to be edited.

3 0200

AWG2021 User Manual