SETUP Menu

Selecting Output Parameter Fields

There are three ways to select a parameter.

1.Press the bottom button for the item to be set. Then select the channel in the side menu and select the field.

2.Press the bottom button for the item. Then press the bottom button again; each time the button is pressed, the CURSOR will move to a different channel. When you reach the desired setting field, set the appropriate value.

3.Press the CURSOR key on the front panel and select the field. When the CURSOR key is pressed again, the cursor moves to the next setting field for that channel.

Numeric Input Use the numeric keys or the general purpose knob to input a numeric into the Clock, Amplitude, and Offset item fields.

1.Press the bottom button for the item to be set.

2.Use the numeric keys or general purpose knob to input the number for the parameter.

When using the numeric keys, press the front panel ENTER key, VALUE key, or the appropriate unit key to enter the number. When this is done, the value will be confirmed and will appear in the icon on the screen.

Each time the general purpose knob is turned, the numeric value is entered. The value in the icon will change accordingly.

Selecting a Waveform or Sequence File

The first step in setting the waveform output parameters is to select the waveform or sequence file.

Each waveform or sequence file has output parameter settings attached. When a file is selected, the output parameters are also automatically changed to the settings for that file. A waveform or sequence file that has just been created with the editor has the default output parameters set.

Clock

100.0 MHz (can also be set using the editor)

Operation

NORMAL

Filter

Through

Amplitude

1 V

Offset

0 V

AWG2021 User Manual

3 ￿217