SETUP Menu
2.Press the Source button in the side menu and set it to Internal. The clock icon shown below will be displayed on the screen.
Since the clock frequency for CH2 depends on the clock frequency for CH1, set the clock frequency for CH1 first.
3.Use the numeric keys or general purpose knob to set the internal clock frequency with the Internal Clock item.
The clock frequency can be set in four digits between 10.00 Hz and 250.0 MHz.
To set the CH2 clock frequency:
4.Select Divider from the side menu. The divider icon shown below will be displayed on the screen.
5.Turn the general purpose knob to set the frequency divider.
The clock frequency for CH2 is determined by setting the value for frequency division of the CH1 clock. This frequency division setting can be selected from the multiples of 2 from 1 (20) to 16,777,216 (224). The CH2 clock frequency, after frequency division, is expressed with the four digits under the frequency division value. Depending on the value of the CH1 clock frequency, it may not be possible to set a large frequency division ratio. For example, if the CH1 clock frequency is 10 Hz, then the only frequency division ratio that can be set is 1.
When the CH2 waveform is changed by pressing Waveform Sequence, the frequency division value is always reset to 1 to give CH2 the same clock frequency as CH1. If you change the clock frequency for CH1, the frequency division ratio stays the same and the clock frequency for CH2 changes.
3 220 | AWG2021 User Manual |