1Descriptions
BCS II SIMPLEX REPEATER
The Broadband Connectivity System II (BCS II) Simplex Repeater (part
#
Features
•Full signal regeneration to equal level point on each circuit
•
•Alarm and tracer lamp LEDs
•Full DSX functionality, including patching, monitoring and loop- backs
SPECIFICATIONS
Electrical
Monitor Level: 20 dB + 1.5 dB below signal level
Return Loss: <
Impedance: 75Ω (+/- 5%)
Power
Battery Input: A and B redundant,
Input Current: 35 mA nominal @ 48V
Internal Fuse: 1/4 amp, not field replaceable