3B-1. Model LLD (Direct Ignition)

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot light. It is equipped with an ignition device which automatically lights the heater. Do NOT try to light the burners by hand.

B.BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Set the thermostat to lowest setting and turn appliance switch to "OFF".

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the heater. Do not try to light the burners by hand.

5.Remove the heater door.

6.Turn gas control knob clockwise to "OFF".

7.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to next step.

8.Turn gas control knob counterclockwise to "ON".

9.Replace control access panel

10.Turn on all electric power to appliance.

11.Set thermostat to desired setting and turn appliance switch from "OFF" to either "POOL" or "SPA".

12.If the appliance will not operate, check that the filter pump is on, the filter is clean and water is flowing to the pool. Otherwise, follow

the instructions "To Turn Off Gas To Appliance" and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting and turn appliance switch to "OFF".

2.Turn off all electric power to the appliance if service is to be performed.

3.Turn gas control knob clockwise to "OFF".

4.Replace control access panel.

Page 15
Image 15
Teledyne LLG dimensions 3B-1. Model LLD Direct Ignition, Do not try to light any appliance

LLD, LLG specifications

Teledyne LLG, LLD is a prominent player in the field of advanced measurement and inspection systems. Based in the heart of the technology sector, Teledyne LLG combines cutting-edge engineering with innovative technologies to deliver high-performance solutions, particularly in the realms of optics and imaging.

One of the main features of Teledyne LLG is its commitment to precision. The company specializes in providing high-resolution sensors and imaging systems that cater to a variety of applications, including scientific research, industrial inspection, and aerospace. These sensors are designed to meet stringent performance standards, ensuring reliable data acquisition and analysis across diverse environments.

The technologies employed by Teledyne LLG are at the forefront of optical engineering. Their systems often utilize sophisticated algorithms and advanced signal processing techniques to enhance image quality and measurement accuracy. Innovations such as spectral imaging enable users to capture and analyze information beyond the visible spectrum, offering valuable insights for applications in fields like remote sensing and environmental monitoring.

Another characteristic that sets Teledyne LLG apart is its focus on integration and customization. Understanding that each application has unique requirements, the company offers tailored solutions that cater to specific needs. This flexibility allows clients from various sectors to leverage Teledyne LLG's technologies effectively, optimizing their operational workflows.

Teledyne LLG’s commitment to research and development ensures that its products continually evolve. The company invests significantly in exploring new materials, sensor designs, and imaging techniques. This proactive approach not only keeps them ahead of market trends but also ensures that their customers benefit from the latest technological advancements.

Moreover, Teledyne LLG places a strong emphasis on sustainability and efficiency. By developing systems that require less energy and produce less waste, the company not only addresses environmental concerns but also helps clients reduce operational costs.

In summary, Teledyne LLG, LLD stands out in the field of measurement and inspection through its precision, innovative technology, customized solutions, and commitment to sustainability. As industries continue to seek advanced solutions to meet modern challenges, Teledyne LLG remains dedicated to providing high-quality imaging and measurement systems that drive progress and innovation across multiple fields. With its strong focus on R&D and customer-centric solutions, Teledyne LLG is well-positioned to lead the future of optical technology and sensor development.