Page 2
Gas Association and Canadian Gas Association) as complying with the latest edition of the Standard for
Certain sections of this manual are specific to either United States or Canadian installations, and are labeled as such.
1B. Description
The Laars Lite LLD heater gets electrical power from an external 120V / 240V (volt AC) source and provides a dual thermostat
The Laars Lite heater is specifically designed for heating swimming pools and spas. Do not use it as a general service water heater or for heating salt water pools. Consult your dealer for the appropriate Tele- dyne Laars products for these applications.
1C. Warranty
The Laars Lite heater is sold with a limited factory warranty. Details are specified on the back cover of this manual. A copy of the warranty and a warranty registration card are included in the plastic bag shipped with the heater. Fill out and return the warranty registration card.
Make all warranty claims to an authorized Teledyne Laars representative or directly to the fac- tory. Claims must include the heater serial number and model (this information can be found on the rating plate), installation date, and name of the installer. Shipping costs are not included in the warranty cover- age.
Damage caused by improper installation or assembly, or to the heat exchanger by corrosive water, is NOT covered by the Warranty. See Section 3D for maintaining proper pool water chemistry.
NOTE: Keep this manual in a safe place for future reference when inspecting or servicing the heater.
1D. Technical Assistance
Consult Teledyne Laars or your local distributor with any questions or problems involving the specifica- tions, installation, and operation of your Teledyne Laars equipment. An experienced technical support staff is ready to assist in assuring the proper perfor- mance and application of Teledyne Laars products.
SECTION 2.
Installation Instructions
2A. General Information
Install the Laars Lite heaters in accordance with the procedures in this manual, local codes and ordi- nances, and in accordance with the latest edition of the National Fuel Gas Code, ANSI Z223.1. In Canada, the installation must be in accordance with
All
1.Field assembly (if required)
2.Appropriate site location (clearances) and flooring
3.Sufficient combustion and ventilation air
4.Properly sized gas meter and piping
5.Proper electrical wiring (if required)
6.Adequate water flow
This manual provides the information needed to meet these requirements. Review all application and installation procedures completely before continuing the installation.
2B. Field Assembly
The Laars Lite heater is shipped from the factory with the top assembly in the
The Laars Lite heater is also certified for installa- tion in an outdoor shelter in Canada when equipped with a drafthood. An outdoor shelter is an enclosure not normally occupied which does not communicate directly with occupied areas.
Check the rating plate on the heater for the correct Teledyne Laars part number. See instructions supplied with the drafthood for installation and attach- ment. When the draft hood is used, locate the heater so as to be in the same atmospheric pressure zone as the combustion air inlet to the heater.
If a drafthood is used, it must be connected to a vent pipe which stops at least 2 feet (0.61 meters [m]) above the highest point of the roof or other object that is within 10 feet (3.05 m) from the vent termination.
The vent pipe must have a listed vent cap which allows a full equivalent opening for flue products (see Figure 2).