Page 14

a) Model LLD Temperature Control

b)Model LLG Temperature Control

Figure 18. Temperature controls.

Figure 19. Pressure switch adjustment.

b.Wait 3 minutes, turn filter pump off.

c.Remove thermometer and Pete's plug.

d.Replace the drain plug.

2G-9. Adjusting the Manual Bypass Valve

After the manual bypass valve is installed, use the following procedures to adjust the bypass valve:

1.Clean pool filter.

2.Remove drain plug located on right-hand side of heater and replace it with a Pete's plug.

3.Insert a pocket thermometer (see Figure 16) through the Pete's plug into the header.

4.Close manual bypass valve.

5.Turn rotary switch to OFF position.

6.Repeat steps 6 through 12 of the temperature rise

test (see Section 2G-8).

7.Open manual bypass valve until temp rise falls between the min. and max. range.

8.Once the temperature is within the correct range, safety wire handle of the manual bypass valve in place and tag valve to prevent change in the water low.

SECTION 3.

Operating Instructions

3A. General Information

With any new pool or spa installation, operate the filter pump with the heater off long enough to com- pletely clean the water. This will remove any installation residue from the water. Clean the filter at the end of this operation before starting the heater. When raising the temperature of a cold pool, remove all time clock settings. This lets the filter system and heater operate continuously until the water reaches the temperature setting on the temperature control. When that happens, the heater will automatically shut off, but the filter pump will keep running.

WARNINGS

Vent pipes, drafthoods, and heater tops get hot! These surfaces can cause serious burns. Do not

touch these surfaces while the heater is in operation. Adding a vent cap reduces the

temperature on the top.

For your safety, when starting the heater, keep your head and face well away from the lower firebox opening to prevent any risk of personal injury.

Keep all objects off the top of the heater. Blocking air flow could damage the heater, and may void the warranty.

3B. Lighting and Shutdown Procedures

NOTE: If your LP tank runs out of fuel, turn off gas at the heater. After the tank is refilled, the heater must be re-lit following the instructions found on the inside of the heater. DO NOT attempt repairs on the gas control or heater. Tampering is dangerous and voids all warranties.

3B-1. Model LLD (see Page 15).

3B-2. Model LLG (see Page 16).

Page 14
Image 14
Teledyne LLD, LLG 3A. General Information, 3B. Lighting and Shutdown Procedures, 2G-9. Adjusting the Manual Bypass Valve

LLD, LLG specifications

Teledyne LLG, LLD is a prominent player in the field of advanced measurement and inspection systems. Based in the heart of the technology sector, Teledyne LLG combines cutting-edge engineering with innovative technologies to deliver high-performance solutions, particularly in the realms of optics and imaging.

One of the main features of Teledyne LLG is its commitment to precision. The company specializes in providing high-resolution sensors and imaging systems that cater to a variety of applications, including scientific research, industrial inspection, and aerospace. These sensors are designed to meet stringent performance standards, ensuring reliable data acquisition and analysis across diverse environments.

The technologies employed by Teledyne LLG are at the forefront of optical engineering. Their systems often utilize sophisticated algorithms and advanced signal processing techniques to enhance image quality and measurement accuracy. Innovations such as spectral imaging enable users to capture and analyze information beyond the visible spectrum, offering valuable insights for applications in fields like remote sensing and environmental monitoring.

Another characteristic that sets Teledyne LLG apart is its focus on integration and customization. Understanding that each application has unique requirements, the company offers tailored solutions that cater to specific needs. This flexibility allows clients from various sectors to leverage Teledyne LLG's technologies effectively, optimizing their operational workflows.

Teledyne LLG’s commitment to research and development ensures that its products continually evolve. The company invests significantly in exploring new materials, sensor designs, and imaging techniques. This proactive approach not only keeps them ahead of market trends but also ensures that their customers benefit from the latest technological advancements.

Moreover, Teledyne LLG places a strong emphasis on sustainability and efficiency. By developing systems that require less energy and produce less waste, the company not only addresses environmental concerns but also helps clients reduce operational costs.

In summary, Teledyne LLG, LLD stands out in the field of measurement and inspection through its precision, innovative technology, customized solutions, and commitment to sustainability. As industries continue to seek advanced solutions to meet modern challenges, Teledyne LLG remains dedicated to providing high-quality imaging and measurement systems that drive progress and innovation across multiple fields. With its strong focus on R&D and customer-centric solutions, Teledyne LLG is well-positioned to lead the future of optical technology and sensor development.