Test Summary

www.ti.com

R25 and R28 can be changed to regulate output.

VBAT = 2.1V × [1+ R25/R28]; for bq2461x;

VBAT = 1.8V × [1+ R25/R28]; for bq2463x;

Adjust the input voltage as required. Output set to operate at 21V (bq2461x) or 18V (bq2463x) from the factory.

2 Test Summary

2.1Definitions

This procedure details how to configure the HPA422 evaluation board. On the test procedure the following naming conventions are followed. See the HPA422 schematic for details.

VXXX:

External voltage supply name (VADP, VBT, VSBT)

LOADW:

External load name (LOADR, LOADI)

V(TPyyy):

Voltage at internal test point TPyyy. For example, V(TP12) means the voltage at TP12

V(Jxx):

Voltage at jack terminal Jxx.

V(TP(XXX)):

Voltage at test point "XXX". For example, V(ACDET) means the voltage at the test

 

point which is marked as "ACDET".

V(XXX, YYY):

Voltage across point XXX and YYY.

I(JXX(YYY)):

Current going out from the YYY terminal of jack XX.

Jxx(BBB):

Terminal or pin BBB of jack xx

Jxx ON:

Internal jumper Jxx terminals are shorted

Jxx OFF:

Internal jumper Jxx terminals are open

Jxx (-YY-) ON:

Internal jumper Jxx adjacent terminals marked as "YY" are shorted

Measure:→ A,B

Check specified parameters A, B. If measured values are not within specified limits the

 

unit under test has failed.

Observe → A,B

Observe if A, B occur. If they do not occur, the unit under test has failed.

Assembly drawings have location for jumpers, test points and individual components.

2.2Equipment

2.2.1Power Supplies

Power Supply #1 (PS#1): a power supply capable of supplying 30-V at 5-A is required.

Power Supply #2 (PS#2): a power supply capable of supplying 5-V at 1-A is required.

Power Supply #3 (PS#3): a power supply capable of supplying 5-V at 1-A is required.

2.2.2LOAD #1

A 30V (or above), 5A (or above) electronic load that can operate at constant current mode

2.2.3LOAD #2

A Kepco bipolar operational power supply/amplifier, 0 ±30V (or above), 0 ±6A (or above).

2.2.4Oscilloscope

Tektronix TDS3054 scope or equivalent, 10X voltage probe.

4

bq2461x/bq2463x EVM (HPA422) Multi-Cell Synchronous Switch-Mode Charger

SLUU396A –January 2010 –Revised July 2010

Copyright © 2010, Texas Instruments Incorporated

Page 4
Image 4
Texas Instruments BQ2463X EVM, BQ2461X manual Definitions, Equipment