www.ti.com | Test Summary |
2.2.5METERS
Seven Fluke 75 multimeters, (equivalent or better)
Or: Four equivalent voltage meters and three equivalent current meters.
The current meters must be capable of measuring 5A+ current
2.3Equipment Setup
1.Set the power supply #1 for 0V ± 100mVDC, 5.0 ± 0.1A current limit and then turn off supply.
2.Connect the output of power supply #1 in series with a current meter (multimeter) to J1 (VIN, GND).
3.Connect a voltage meter across J1 (VIN, GND).
4.Set the power supply #2 for 0V ± 100mVDC, 1.0 ± 0.1A current limit and then turn off supply.
5.Connect the output of the power supply #2 to J4 and J5 (TS, GND).
6.Connect Load #1 in series with a current meter to J5 (SYS, GND). Turn off Load #1
7.Connect Load #2 in series with a current meter to J5 (BAT, GND). Turn off Load #2.
8.Connect a voltage meter across J5 (BAT, GND).
9.Connect an oscilloscope's probe across J5 (BAT, GND)
10.Connect a voltage meter across J5 (SYS, GND).
11.JP1 (TTC and HI): ON, JP2: ON, JP3 (VPULLUP and VREF): ON, JP4: ON, JP5: OFF.
After the above steps, the test setup for HPA422 is shown in Figure 1.
bq24610/616/617/30EVM
J1
HPA422
PH
Power supply#1
| I |
Iin | V |
|
ACPWR TP1
ACPWR
PGND
TP2
J3
VCC
ACSET
ISET1
ISET2
GND
U1
JP4
APPLICATIONCIRCUIT
TP12
SYS
J5
SYS
BAT
TP9 PGND
VBAT
Isys
|
| I | Load |
V |
|
| |
|
| #1 | |
|
|
| |
|
| I | Load |
V | Ibat |
| |
| #2 | ||
|
|
| |
|
| Oscilloscope | |
|
|
| I |
| VREF |
J2 | JP3 |
|
VEXT | VEXT |
|
|
HI |
|
| |
GND |
|
| |
L | JP1 |
| |
TTC | O | JP2 | JP5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
/ACDRV | /BATDRV | CE | PG | /STAT1 | /STAT2 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
J4
PG
STAT1
VREF
TS
Power |
sup ply#2 |
Figure 1. Original Test Setup for HPA422 (bq2461x/bq2463x EVM)
SLUU396A | bq2461x/bq2463x EVM (HPA422) | 5 |