1.2 Use of the DEM-DAI3010

Use of the DEM-DAI3010

1.2 Use of the DEM-DAI3010

The DEM-DAI3010 is shipped with standard settings preset. Therefore, connecting power supplies (15-V, –15-V and 5-V) is the only requirement to prepare the board for use, unless nonstandard settings are desired.

1.2.1Initial Settings of the DEM-DAI3010 (at shipping)

Table 1–1. Initial Settings of the DEM-DAI3010 at Shipping

Item

Initial Setting (at shipping)

Power supply voltage

15 V, –15 V, and 5 V (close CN57)

 

 

Power supply terminals

CN51–CN55 (open CN56)

 

 

Connection of PCM3010 and S/PDIF I/O

DIR1703 and DIT4096 connected with JP107

 

 

DIR1703 system clock (SCK)

256 fS

DIR1703 output audio data format

I2S

DIR1703 crystal clock frequency

24.576 MHz (load capacitance: 18 pF)

 

 

DIT4096 system clock (SCLK)

256 fS

DIT4096 input audio data format

I2S

PCM3010 system clock

Automatic selection (no setting required)

 

 

PCM3010 I/O audio data format

I2S

PCM3010 power-down function

Disabled

 

 

PCM3010 de-emphasis function (DAC)

Disabled

 

 

PCM3010 DAC cutoff frequency

54 kHz (JP101–JP104 are closed)

 

 

PCM3010 ADC input terminal selection

CN101, CN102: 2-V rms input (with LPF)

1.2.2How to Connect Power Supplies to the DEM-DAI3010

The DEM-DAI3010 requires 5-V, 15-V, and –15-V power supplies. Power is supplied to this board by five binding posts (one each for VCC = +5 V, +AVCC

=+15 V, –AVCC= –15 V, and two for ground) from stabilized dc power supplies. VDD (3.3 V) for the PCM3010 is normally generated by an onboard voltage-regulator IC from VCC (5 V), but it is possible to supply 3.3 V directly. To do so, open CN057, then supply 3.3 V to CN056 and 5 V to CN054. If 3.3

V is supplied externally, 5 V must still be provided to CN054 in order to supply the analog section of the PCM3010. To avoid latch-up of the PCM3010, ensure that VCC and VDD are powered up simultaneously.

Table 1–2. Power Supply Terminals and Supply Voltage (Depending on CN057 Setting)

Power Terminal

CN057 Closed (Default)

CN057 Open

CN051 (orange)

15 V

15 V

 

 

 

 

 

CN052 (green)

0

V (ground)

0

V (ground)

 

 

 

CN053 (blue)

–15 V

–15 V

 

 

 

 

 

CN054 (red)

5

V

5

V

 

 

 

 

 

CN055 (black)

0

V (ground)

0

V (ground)

 

 

 

CN056 (2-pin connector)

Open (no connection)

3.3 V

 

 

 

 

 

Description1-3

Page 9
Image 9
Texas Instruments Use of the DEM-DAI3010, Initial Setting at shipping, Power Terminal, CN057 Closed Default, CN057 Open