Texas Instruments THS4150 manual ±5. VICR Level Shifter, Introduction and Description

Models: THS4150

1 26
Download 26 pages 10.95 Kb
Page 12
Image 12
Figure 1±5. VICR Level Shifter

Additional Sample Schematics

Figure 1±5. VICR Level Shifter

 

 

 

 

 

 

R6B

 

 

 

 

 

VCC

402 Ω

 

 

RX3

 

RPU1

C4

 

 

49.9 Ω

 

 

 

 

VCC

 

50 Ω

 

 

 

 

 

 

RX1

R1b

R3b

 

 

 

 

Source

 

 

+

 

 

 

 

 

 

 

 

VIN

0 Ω

0 Ω

374 Ω

 

 

±

 

 

 

THS4150

 

AC

 

Rx0

R3a

 

 

 

 

 

 

+

 

 

 

24.9 Ω

374 Ω

 

 

±

 

 

 

 

 

 

 

 

 

 

 

C1

VOCM

VCC±

C6

 

 

 

RPU2

 

 

 

 

 

 

 

 

R6a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

402 Ω

 

R4b

Rx4

R10

0 Ω

0 Ω

49.9 Ω

R4a

Rx5

Rx6

0 Ω

0 Ω

49.9 Ω

Note: Shifting the VICR within the specified range in the data sheet via RPU1 and RPU2 if the VICR is out of the specified range. See the Application section of the data sheet for the THS4150 for more information.

Figure 1±6. Butterworth Filter With Multiple Feedback.

RX3

RX1R1B

1 dBm

AC

R7

RX2 R1A

R2B

 

 

 

 

C1B

 

 

 

VCC

 

R3B

+

5 V

R10

 

±

 

C2

 

 

THS4150

RX7

R3A

±

+

 

 

 

 

 

±5 V

 

 

VCC±

 

R2A

C1A

 

 

 

 

 

Note: Butterworth filter implemented with multiple feedback architecture

1-6

Introduction and Description

Page 12
Image 12
Texas Instruments THS4150 manual ±5. VICR Level Shifter, Introduction and Description, Additional Sample Schematics