Texas Instruments 5.TPA3001D1EVM Gain Settings, Evaluation Module Preparations, Control Inputs

Models: TPA3001D1EVM

1 22
Download 22 pages 13.22 Kb
Page 18
Image 18
Table 2–5. TPA3001D1EVM Gain Settings

Quick Start List for Stand-Alone Operation

Evaluation Module Preparations

6)Adjust the source signal level as needed.

7)Use jumpers GAIN0 and GAIN1 to set the gain as shown in Table 2–5.

Table 2–5. TPA3001D1EVM Gain Settings

GAIN1

GAIN0

 

GAIN (dB)

 

 

 

 

ON

ON

 

12

 

 

 

 

ON

OFF

 

18

 

 

 

 

OFF

ON

 

23.6

 

 

 

 

OFF

OFF

 

36

Note: ON = Jumper installed,

OFF = Jumper NOT installed

 

Control Inputs

Note:

The control signals applied to the EVM shutdown inputs must have sufficient current capability to overcome the 120–kpullup resistor on each input.

Holding down S1 places the amplifier in the shutdown state. Releasing S1 returns the amplifier to the active state.

Refer to the TPA3001D1 data sheet (SLOS398) for logic threshold voltage ratings.

8)SHUTDOWN: This pin is active low. A low on this pin shuts down the ampli- fier; a high on this pin places the amplifier in an active state. Leaving this pin floating also allows normal amplifier operation.

Power Up

9)Verify correct voltage and input polarity and set the external power supply to ON. The EVM should begin operation.

10)Adjust the signal source level as needed.

2-6