| LXM32M | 
 | 
 | 5 Commissioning | |
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| Parameter name | Description | Unit | Data type | Parameter address | 
| HMI menu | 
 | Minimum value | R/W | via fieldbus | 
| HMI name | 
 | Factory setting | Persistent | 
 | 
| 
 | 
 | Maximum value | Expert | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| EthIPmaster1 | IP address master, byte 1 | - | UINT16 | CANopen 3044:29h | 
| 
 | IP address of the master that is permitted to | 0 | UINT16 | Modbus 17490 | 
| 
 | 0 | UINT16 | Profibus 17490 | |
| 
 | perform Modbus TCP I/O scanning. | 255 | UINT16 | CIP 168.1.41 | 
| 
 | If set to 0.0.0.0 (default), any master can | |||
| 
 | 
 | R/W | 
 | |
| 
 | perform I/O scanning. | 
 | 
 | |
| 
 | 
 | per. | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | Setting can only be changed if power stage | 
 | - | 
 | 
| 
 | is disabled. | 
 | 
 | 
 | 
| 
 | Changed settings become active immedi- | 
 | 
 | 
 | 
| 
 | ately. | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| EthIPmaster2 | IP address master, byte 2 | - | UINT16 | CANopen 3044:2Ah | 
| 
 | Setting can only be changed if power stage | 0 | UINT16 | Modbus 17492 | 
| 
 | 0 | UINT16 | Profibus 17492 | |
| 
 | is disabled. | 255 | UINT16 | CIP 168.1.42 | 
| 
 | 
 | |||
| 
 | Changed settings become active immedi- | 
 | R/W | 
 | 
| 
 | ately. | 
 | per. | 
 | 
| 
 | 
 | 
 | - | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| EthIPmaster3 | IP address master, byte 3 | - | UINT16 | CANopen 3044:2Bh | 
| 
 | Setting can only be changed if power stage | 0 | UINT16 | Modbus 17494 | 
| 
 | 0 | UINT16 | Profibus 17494 | |
| 
 | is disabled. | 255 | UINT16 | CIP 168.1.43 | 
| 
 | 
 | |||
| 
 | Changed settings become active immedi- | 
 | R/W | 
 | 
| 
 | ately. | 
 | per. | 
 | 
| 
 | 
 | 
 | - | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| EthIPmaster4 | IP address master, byte 4 | - | UINT16 | CANopen 3044:2Ch | 
| 
 | Setting can only be changed if power stage | 0 | UINT16 | Modbus 17496 | 
| 
 | 0 | UINT16 | Profibus 17496 | |
| 
 | is disabled. | 255 | UINT16 | CIP 168.1.44 | 
| 
 | 
 | |||
| 
 | Changed settings become active immedi- | 
 | R/W | 
 | 
| 
 | ately. | 
 | per. | 
 | 
| 
 | 
 | 
 | - | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
5.7.3Setting the mapping for I/O scanning
The input mapping is set by means of the parameters
EthOptMapInp1 ... EthOptMapInp3.
The output mapping is set by means of the parameters
EthOptMapOut1 ... EthOptMapOut3.
▶Set the desired mapping values with the parameters
EthOptMapInp1 ... EthOptMapInp3 and EthOptMapOut1 ...
EthOptMapOut3.
0198441113843, V1.01, 01.2012
| 47 | 