Schneider Electric LXM32M manual Operating mode Homing

Models: LXM32M

1 82
Download 82 pages 58.08 Kb
Page 62
Image 62

6 Operation

LXM32M

 

 

6.2.9Operating mode Homing

Starting the operating mode The operating mode is set and started in the process data channel with the transmit data (master to slave).

Method

dmControl

Reference value RefA32

Reference value RefB32

 

Bits 0 ... 6

 

 

 

MODE+ACTION

 

 

 

 

 

 

Position setting

06h

-

As HMp_setP

Reference movement

26h

As HMmethod

-

Status information The word "driveStat" provides information on the operating mode.

Bit

Name

Meaning

 

 

 

13

X_ADD1

Reserved

 

 

 

14

X_END

0: Operating mode started

 

 

1: Operating mode terminated

 

 

 

15

X_ERR

0: No error

 

 

1: Error

 

 

 

Terminating the operating mode The operating mode is terminated when the motor is at a standstill and one of the following conditions is met:

Homing successful

Stop caused by "Halt" or "Quick Stop"

Stop caused by an error

0198441113843, V1.01, 01.2012

62

Modbus-TCP module

Page 62
Image 62
Schneider Electric LXM32M manual Operating mode Homing