LXM32M

 

3 Basics

 

driveInput The word "driveInput" is used to indicate the status of the digital signal

 

inputs.

 

 

 

 

 

 

 

bit

Signal

Factory setting

 

 

 

 

 

0

DI0

Signal input function Freely Available

 

1

DI1

Signal input function Reference Switch (REF)

 

2

DI2

Signal input function Positive Limit Switch (LIMP)

 

3

DI3

Signal input function Negative Limit Switch (LIMN)

 

4

DI4

Signal input function Freely Available

 

5

DI5

Signal input function Freely Available

 

6 ... 15

-

Reserved

_p_act The double word "_p_act" indicates the actual position. The value cor- responds to the parameter _p_act.

_v_act The double word "_v_act" indicates the actual velocity. The value cor- responds to the parameter _v_act.

_I_act The word "_I_act" is used to provide information on the total motor current. The value corresponds to the parameter _I_act.

EthOptMapInp1 ... EthOptMapInp3 The double words EthOptMapInp1 ... EthOptMapInp3 contain selecta- ble parameters. The product manual provides descriptions of the parameters EthOptMapInp1 ... EthOptMapInp3 which explain parame- ter mapping.