4 Installation

LXM32M

 

 

 

4.2

Electrical installation

 

 

Cable specifications

 

 

 

Shield:

Required, both ends grounded

 

 

 

 

 

 

 

 

Twisted Pair:

Required

 

 

 

 

 

 

PELV:

Required

 

 

 

 

 

 

Cable composition:

8 * 0.25 mm2 (8 * AWG 22)

 

 

Maximum cable length:

100 m

 

 

 

 

 

 

Special features:

-

 

 

 

 

Pin assignment

Note the pertinent information on equipotential bonding conductors in the product manual.

Use pre-assembled cables to reduce the risk of wiring errors.

Slot 3

8

 

7

 

 

6

 

 

5

 

8

4

A

A

3

 

2

 

1

 

1

 

8

8

 

B

7

 

6

B

1

5

 

 

 

4

 

 

3

 

 

2

 

 

1

 

Figure 5: Pin assignment

Pin

Signal

Meaning

 

 

 

1

Tx+

Ethernet transmit signal +

2

Tx-

Ethernet transmit signal -

3

Rx+

Ethernet receive signal +

4

-

-

5

-

-

6

Rx-

Ethernet receive signal -

7

-

-

8

-

-

0198441113843, V1.01, 01.2012

36

Modbus-TCP module

Page 36
Image 36
Schneider Electric LXM32M manual Electrical installation, Pin Signal Meaning