LXM32M

5 Commissioning

 

 

5.3Setting the transmission rate

The parameter EthRateSet lets you set the transmission rate.

Set the desired transmission rate with the parameter EthRateSet.

Parameter name

Description

Unit

Data type

Parameter address

HMI menu

 

 

Minimum value

R/W

via fieldbus

HMI name

 

 

Factory setting

Persistent

 

 

 

 

Maximum value

Expert

 

 

 

 

 

 

EthRateSet

Transmission rate setting

-

UINT16

CANopen 3044:2h

 

0

/ Autodetect: Autodetect

0

UINT16

Modbus 17412

 

0

UINT16

Profibus 17412

 

1

/ 10 Mbps Full: 10 Mbps full duplex

 

4

UINT16

CIP 168.1.2

 

2

/ 10 Mbps Half: 10 Mbps half duplex

 

 

R/W

 

 

3

/ 100 Mbps Full: 100 Mbps full duplex

 

 

 

 

per.

 

 

4

/ 100 Mbps Half: 100 Mbps half duplex

 

 

 

 

-

 

 

 

 

 

 

 

Changed settings become active immedi-

 

 

 

 

ately.

 

 

 

 

 

 

 

 

 

5.4Setting the protocol

The protocol is set by means of the parameter EthMode.

Set the parameter EthMode to "Modbus TCP".

Parameter name

Description

Unit

Data type

Parameter address

HMI menu

 

Minimum value

R/W

via fieldbus

HMI name

 

Factory setting

Persistent

 

 

 

Maximum value

Expert

 

 

 

 

 

 

EthMode

Protocol

-

UINT16

CANopen 3044:1h

ConF CoM-

0 / Modbus TCP / MtCP : Modbus TCP I/O

0

UINT16

Modbus 17410

1

UINT16

Profibus 17410

EtMd

scanning is enabled

1

UINT16

CIP 168.1.1

1 / EtherNet/IP / EtiP : EtherNet/IP commu-

 

 

R/W

 

 

nication is enabled

 

per.

 

 

NOTE: Modbus TCP parameter access is

 

-

 

 

possible irrespective of the selected setting.

 

 

 

 

Changed settings become active the next

 

 

 

 

time the product is switched on.

 

 

 

 

 

 

 

 

0198441113843, V1.01, 01.2012

Modbus-TCP module

43

Page 43
Image 43
Schneider Electric LXM32M manual Setting the transmission rate, Setting the protocol