| LXM32M | 6 Operation | 
| 
 | 
 | 
6.2.6Operating mode Profile Torque
Starting the operating mode The operating mode is set and started in the process data channel with the transmit data (master to slave).
| dmControl | Reference value RefA32 | Reference value RefB32 | 
| Bits 0 ... 6 | 
 | 
 | 
| MODE+ACTION | 
 | 
 | 
| 
 | 
 | 
 | 
| 24h | As PTtq_target | As RAMP_tq_slope | 
Status information The word "driveStat" provides information on the operating mode.
| Bit | Name | Meaning | 
| 
 | 
 | 
 | 
| 13 | X_ADD1 | 0: Target torque not reached | 
| 
 | 
 | 1: Target torque reached | 
| 
 | 
 | 
 | 
| 14 | X_END | 0: Operating mode started | 
| 
 | 
 | 1: Operating mode terminated | 
| 
 | 
 | 
 | 
| 15 | X_ERR | 0: No error | 
| 
 | 
 | 1: Error | 
| 
 | 
 | 
 | 
Terminating the operating mode The operating mode is terminated when the motor is at a standstill and one of the following conditions is met:
•Stop caused by "Halt" or "Quick Stop"
•Stop caused by an error
0198441113843, V1.01, 01.2012
| 59 | 