![2.2 Quick Start List for Platform](/images/new-backgrounds/16961/1696131x1.webp)
Quick Start List for Platform
2.2 Quick Start List for Platform
Follow these steps when using the TPA6030A4EVM with the TI
Note:
The TI
-Platform Preparations
1)Ensure that all external power sources are set to OFF and that the platform power switch S1 is set to OFF.
2)Install a TPA6030A4 module in platform socket U2, taking care to align the module pins correctly.
3)Use switch S2 to select or bypass the signal conditioning EVM (U1).
4)Set jumper JP6 to select the Mode control input.
5)Remove jumper JP5.
Table
EVM | JP5 | JP6 | JP7 | JP8 | S2 | S3 |
Off | Mode | X | Hi | Note 4 | X |
Notes: 1) X = Don’t care
2)ON = Shunt installed
3)OFF = Open
4)Set S2 to ON when signal conditioning board is installed in U1; set S2 to OFF when no signal conditioning board is installed.
-Power Supply
6)Select and connect an external regulated power supply (ensure power
supply is turned OFF) set from 7 V to 15 V to platform VCC power input connector J1, taking care to observe marked polarity. Jumper the
appropriate power input.
-Inputs and Outputs
7)Ensure that the audio signal source level is set to minimum.
8)Connect the audio source to left and right RCA phono jacks J3 and J5 or stereo miniature phone jack J4.
9)Connect speakers to left and right RCA jacks J7 and J9 or to stripped wire speaker connectors J8.