Quick Start List for
2.3 Quick Start List for Stand-Alone
Follow these steps to use the TPA6030A4EVM
Figure 2–3. Quick Start Module Map
86
7 |
-Power Supply
1)Ensure that all external power sources are set to OFF.
2)Connect an external regulated power supply set from 7 V to 15 V to the module VCC and GND pins taking care to observe marked polarity.
-Inputs and Outputs
3)Ensure that audio signal source level adjustments are set to minimum.
4)Connect the right (or left) positive lead of the audio source to the module
R LINE+ (or L LINE+) pins and the negative lead to the R LINE– (or L
5)Select output mode:
a)For BTL output, connect a speaker to the module OUT+ and OUT– pins of each channel, (see Figure
or
b)For
Quick Start |