Typical Performance Data | www.ti.com |
Efficiency at Vin = 230V RMS
| 99.0% |
|
|
|
|
|
|
|
|
|
| 97.0% |
|
|
|
|
|
|
|
|
|
| 95.0% |
|
|
|
|
|
|
|
|
|
(%) |
|
|
|
|
|
|
|
|
|
|
Efficiency | 93.0% |
|
|
|
|
|
|
|
|
|
91.0% |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
| 89.0% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| With Phas e M anage m e nt |
| ||
| 87.0% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Without Phas e M anage m e nt |
| ||
| 85.0% |
|
|
|
|
|
|
|
|
|
| 10% | 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% | 100% |
|
|
|
|
| % Output Pow er |
|
|
|
|
Figure 6. Efficiency at 230 VRMS, With and Without Phase Management
Amplitude(A)
1.40706 VIN =230VRMS
1.17256
0.93805
0.70354
0.46904
0.23453
0.00002
0 | 6 | 12 | 18 | 24 | 30 | 36 | 42 | 48 |
HarmonicNo.
Figure 7. Current Harmonics
6 | UCC28060EVM | |
|