Table of Contents |
| ||
1. | Intended Application for Vehere | 1 | |
2. | Specifications & Capacities | 1 | |
| 2.1 | Vehere Diagram | 2 |
3. | Installation | 2 | |
| 3.1 | Location | 2 |
|
| 3.1A Improper Installation | 2 |
|
| 3.1B In humid area, no ducting | 3 |
|
| 3.1C In humid area, duct inlet and/or outlet | 4 |
|
| 3.1D In remote area, duct inlet & outlet | 4 |
| 3.2 | Mounting the Humidity Sensor/Controller | 5 |
| 3.3 | Electrical Requirements | 5 |
| 3.4 | Condensate Removal | 5 |
| 3.5 | Ducting | 5 |
|
| 3.5A Ducting kit | 5 |
|
| 3.5B Ducting for Dehumidification | 6 |
4. | Operation | 6 | |
| 4.1 | Humidity Control | 6 |
| 4.2 | Humidity Control Adjustment | 6 |
| 4.3 | Fan Switch | 6 |
| 4.4 | Automatic Defrost Control | 6 |
| 4.5 | Automatic Low Pressure Control | 6 |
5. | Ventilation | 7 | |
| 5.1 | Ventilation Recommendations | 7 |
6. | Maintenance | 7 | |
| 6.1 | Air Filter | 7 |
7. | Service | 7 | |
| 7.1 | Technical Description | 7 |
| 7.2 | Troubleshooting | 7 |
| 7.3 | Refrigerant Charging | 8 |
| 7.4 | Blower Replacement | 8 |
| 7.5 | Low Pressure Control | 8 |
| 7.6 | Relay | 8 |
8. | Vehere Accessories | 8 | |
9. | Vehere Electrical Wiring Diagram | 9 | |
10. Service Parts | 10 | ||
11. | Warranty | 11 |
1 Intended Application
The intended application for the Vehere is as a pool & spa area humidity sensing controller applied either as a
2 Specifications
Model:
Electrical:
Compressor LRA: 64.5 Amps
Capacity: 184 pints/day @ 80°F, 60% RH
Air Flow: 540 CFM without external ducting 510 CFM @ .15 IWG external static
Refrigerant Charge: 2 lbs., 13 oz.
Optional Duct Connections: 12” round inlet & outlet
Size (w/o duct collars): 36.5” Long x 19” Wide x 40” High
Weight: 180 lbs.
Controller Accuracy: +/- 5% RH @ 72°F
Capacities
The Vehere is designed to control humidity for indoor pool (spa, hot tub) areas. It consists of a controller, dehumidifying cooling system, filter, fan and delivers the following dehumidification capacities:
Air Temp/Relative Humidity | Lbs./Hour | Lbs./Day |
80°F/80%RH | 0.34 | 248 |
82°F/60%RH* | 8.336 | 200 |
80°F/60%RH | 8.04 | 193 |
|
|
| 60°F/80%RH | 7.17 | 172 |
| |
Read these installation, operation and service |
|
|
|
| |||
instructions carefully before installing and using this | Air Temp/Relative Humidity | Pints/Hour | Pints/Day | ||||
unit. Proper adherence to these instructions is essential | 80°F/80%RH | 9.92 | 238 |
| |||
to obtain maximum benefit from your Vehere pool & spa |
| ||||||
82°F/60%RH* | 7.95 | 191 |
| ||||
humidity controller. |
| ||||||
80°F/60%RH | 7.71 | 184 |
| ||||
|
|
|
| ||||
|
|
| 60°F/80%RH | 6.67 | 160 |
| |
• If used near a pool or spa, be certain there is NO | Air Temp/Relative Humidity | BTUs/Hour | KWH/Day | ||||
chance the unit could roll into the water or be | |||||||
|
| (derived) | |||||
splashed and that it is plugged into a GROUND FAULT |
|
| |||||
80°F/80%RH | 5313 | 37.1 |
| ||||
INTERRUPTER. |
| ||||||
82°F/60%RH* | 3114 | 35.3 |
| ||||
• DO NOT use the Vehere as a bench or table. |
| ||||||
80°F/60%RH | 2680 | 34.3 |
| ||||
• Avoid discharging the exhaust directly at people or |
| ||||||
60°F/80%RH | 0869 | 27.5 |
| ||||
pets. |
| ||||||
*ASHRAE Recommended Conditions |
|
| |||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
www.thermastor.com • sales@thermastor.com |