2
www.thermastor.com • sales@thermastor.comToll-Free 1-800-533-7533
1 Intended Application
The intended application for the Vehere is as a pool &
spa area humidity sensing controller applied either as a
free-standing device directly in the pool area or operated
remotely to provide dehumidified air to the pool or spa
area using optional ducting and remotely mounting the
humidity controller. The Vehere high efficiency dehumidifier
utilizes refrigeration to cool an incoming air stream below
its dewpoint as it passes through an evaporator coil. This
cooling results in the removal of moisture (latent heat).
The cooled and dried air is used to pre-cool the incoming
air stream resulting in up to a 200 percent increase in
overall efficiency.
2 Specifications
Model: HI-E Dry Vehere (4025276)
Electrical: 110-120 VAC, 12.0 Amps, grounded
(7’ power cord included)
Compressor LRA: 64.5 Amps
Capacity: 184 pints/day @ 80°F, 60% RH
Air Flow: 540 CFM without external ducting
510 CFM @ .15 IWG external static
Refrigerant Charge: 2 lbs., 13 oz. R-22
Optional Duct Connections: 12” round inlet & outlet
Size (w/o duct collars): 36.5” Long x 19” Wide x 40” High
Weight: 180 lbs.
Controller Accuracy: +/- 5% RH @ 72°F
Capacities
The Vehere is designed to control humidity for indoor
pool (spa, hot tub) areas. It consists of a controller,
dehumidifying cooling system, filter, fan and delivers the
following dehumidification capacities:
Air Temp/Relative Humidity Lbs./Hour Lbs./Day
80°F/80%RH 10.34 248
82°F/60%RH* 8.336 200
80°F/60%RH 8.04 193
60°F/80%RH 7.17 172
Air Temp/Relative Humidity Pints/Hour Pints/Day
80°F/80%RH 9.92 238
82°F/60%RH* 7.95 191
80°F/60%RH 7.71 184
60°F/80%RH 6.67 160
Air Temp/Relative Humidity BTUs/Hour KWH/Day
(derived)
80°F/80%RH 15313 37.1
82°F/60%RH* 13114 35.3
80°F/60%RH 12680 34.3
60°F/80%RH 10869 27.5
*ASHRAE Recommended Conditions
Read these installation, operation and service
instructions carefully before installing and using this
unit. Proper adherence to these instructions is essential
to obtain maximum benefit from your Vehere pool & spa
humidity controller.
• If used near a pool or spa, be certain there is NO
chance the unit could roll into the water or be
splashed and that it is plugged into a GROUND FAULT
INTERRUPTER.
DO NOT use the Vehere as a bench or table.
• Avoid discharging the exhaust directly at people or
pets.
Table of Contents
1. Intended Application for Vehere ..............................1
2. Specifications & Capacities ....................................1
2.1 Vehere Diagram...............................................2
3. Installation ............................................................2
3.1 Location .........................................................2
3.1A Improper Installation .................................2
3.1B In humid area, no ducting .........................3
3.1C In humid area, duct inlet and/or outlet .......4
3.1D In remote area, duct inlet & outlet .............4
3.2 Mounting the Humidity Sensor/Controller ..........5
3.3 Electrical Requirements ...................................5
3.4 Condensate Removal .......................................5
3.5 Ducting ...........................................................5
3.5A Ducting kit ...............................................5
3.5B Ducting for Dehumidification .....................6
4. Operation .............................................................6
4.1 Humidity Control..............................................6
4.2 Humidity Control Adjustment ............................6
4.3 Fan Switch ......................................................6
4.4 Automatic Defrost Control ................................6
4.5 Automatic Low Pressure Control .......................6
5. Ventilation ............................................................7
5.1 Ventilation Recommendations ..........................7
6. Maintenance .........................................................7
6.1 Air Filter ..........................................................7
7. Service .................................................................7
7.1 Technical Description .......................................7
7.2 Troubleshooting ...............................................7
7.3 Refrigerant Charging ........................................8
7.4 Blower Replacement ........................................8
7.5 Low Pressure Control .......................................8
7.6 Relay ..............................................................8
8. Vehere Accessories ................................................8
9. Vehere Electrical Wiring Diagram ............................9
10. Service Parts .......................................................10