Therma-Stor Products Group HI-E Dry Vehere owner manual Installation in humid area with ducting

Models: HI-E Dry Vehere

1 11
Download 11 pages 21.41 Kb
Page 4
Image 4

Optional Quiet-Vent

Direct Warm & Dry Air

Toward Window Glass

Exhaust Ventilator

 

Low = 165 CFM

 

high = 290 CFM

 

Quiet-V

 

ent

 

Vehere Pool & Spa

 

Humidity Controller

 

Dehumidistats

 

for Quiet-Vent and

 

remote Vehere

 

Figure 4: Installation in humid area with ducting.

3.1C In Humid Area, Duct Inlet and/or Outlet

If the pool room is very large or has high ceilings, dehumidification can be improved by adding an inlet and/or outlet duct to circulate and destratify stagnant areas. Add inlet or outlet ducting to create flow across the area’s greatest length. For areas with ceilings higher than 12’, use an inlet duct to draw warm, moist air from near the ceiling. See section 4.5 for attaching duct collars & ducting. (See Fig. 4)

3.1D In Remote Area, Duct Inlet & Outlet

It is often desirable, to install the Vehere in an adjacent equipment room or unfinished area. Air is then transferred between the humid room and the unit via ducting. Remotely mount the Vehere humidity control in the humid room and wire to the Vehere. Local electrical codes must be followed when wiring the control. Refer to the “Mounting the Humidity Sensor/Controller” section which follows. (See Fig. 5)

Optional Quiet-Vent Exhaust Ventilator Low = 165 CFM high = 290 CFM

Quiet-V

ent

Vehere Pool & Spa

Humidity Controller

Direct Warm & Dry Air

Toward Window Glass

Dehumidistats

for Quiet-Vent and

remote Vehere

Figure 5: Installation in remote area with ducting.

Toll-Free 1-800-533-7533

www.thermastor.com • sales@thermastor.com

Page 4
Image 4
Therma-Stor Products Group HI-E Dry Vehere owner manual Installation in humid area with ducting