Therma-Tru Pre-hung Door Systems cont. Check and prepare opening, to check both sides

Models: Pre-hung Door Systems

1 10
Download 10 pages 15.33 Kb
Page 3
Image 3
2 cont. Check and prepare opening.

2 cont. Check and prepare opening.

String test for plumb: Attach string diagonally across the opening from the outside. The string should gently touch, if not the opening is out of plumb by twice that distance and needs to be corrected. . Flip string over itself

to check both sides.

*An “out of plumb” condition is one of the most common reasons doors leak.

Recommended: Weather Resistant Barrier & Flashing Detail.

We recommend the use of Weather Resistant Barrier applied to the exterior sheathing (OSB or other) and the use of an

adhesive or flexible flashing to seal it. The WRB should be cut in the opening (followto check both sides. manufacturer’s instructions) para verificar ambos lados.

with the head of the flap taped up to be sealed later in Step 11. The flashing should be applied in an overlapping manner as shown always working from the bottom up (follow manufacturer’s instructions).

Manual background Revise y prepare el espacio La puerta.

Prueba de la cuerda: Fije la cuerda diaonlmente a traves` de la abertura desde el exterior. La cuerda debra`cruzarse en el centro despues` que se haya fijado en los cuato lados

del marco. La cuerda debera cruzarse suavenente en el centro.

 

`

 

Una separacion en el centro indica que esta “pellizcada” o

`

 

`

que no estan` adecuadamente entrecruzadas. La cuerda debera`

tocarse en el centro. Dele`

vuelta a la cuerda sobre si`misma

para verificar ambos lados.

*Esta es ina de las razones mas` comunes por las cuales una puerta gotea.

Page 3
Image 3
Therma-Tru Pre-hung Door Systems cont. Check and prepare opening, Revise y prepare el espacio La puerta