Therma-Tru Pre-hung Door Systems cont. Caulk sill bottom, Elastomeric or Polyurethane

Models: Pre-hung Door Systems

1 10
Download 10 pages 15.33 Kb
Page 5
Image 5
3 cont. Caulk sill bottom.

3 cont. Caulk sill bottom.

Note: Do not caulk the bottom of the sill if you are using a sill pan.

Lay door unit on edge or face so that bottom side of sill can be caulked. Place very large beads of caulk across full width of sill. Additionally, place “Elastomeric or Polyurethane caulk” along the junction of the sill and jamb and on the bottom surface of the jambs and brickmold.

Elastomeric or Polyurethane

caulk must be used.

Note:

If sill extender is used, place a large bead of caulk at the junction of the extender and the sill approach.

Important!

Apply sealant to back side of brickmould around perimeter of the door. A 1/2”- 5/8” bead of “Elastomeric or Polyurethane caulk” is essential.

Elastomeric or Polyurethane

caulk must be used.

Enmasille el subsuelo y la parte infferior del umbral.

Apoye la puerta sobre un borde o sobre una superficie para poder enmasillar la parte inferior del umbral. Aplique una gran cantidad de masilla a todo lo ancho del umbral. Aplique tembien masilla a lo largo de la union con el marco y en la superficie inferior de los marcos y molduras.

Page 5
Image 5
Therma-Tru Pre-hung Door Systems cont. Caulk sill bottom, Elastomeric or Polyurethane, caulk must be used