REFRIGERATION 48-INCH SIDE-BY-SIDE REFRIGERATOR

Models: KBUIT4855E, KBUIT4865E, KBUDT4855E, KBUDT4865E, KBUIT4875E, KBUDT4875E

REFRIGERATION

*83 3/8"

(211.8 cm)

Width dimensions were measured from trim edge to trim edge.

Height dimensions are shown with leveling legs extended 1/8" (3 mm) below the rollers.

*When leveling legs are fully extended to 1 1/4" (32 mm) below rollers, add 1 1/8" (29 mm) to the height dimensions.

*83 3/8"

(211.8 cm)

25 3/8"

(64.5 cm)

23 1/2"

(59.7 cm)

84" (213.4 cm) Power Cord

The depth from the front of the top grille to the back of the refrigerator cabinet is 25 1/8" (64 mm).

The water line attached to the back of the refrigerator is 5 ft (1.5 mm) long. Height dimensions are shown with leveling legs extended 1/8" (3 mm) below rollers.

*When leveling legs are fully extended to 1 1/4" (32 mm) below rollers, add 1 1/8" (29 mm) to the height dimensions.

*3 1/2" (8.9 cm

SIDE-BY-SIDE

48 1/4" (123 cm)

80" - 90"

(203-229 cm)

4"

(10.2 cm)

14 3/8" (36.5 cm)

83 1/2" (212.1 cm) min.

84 3/4" (215 cm) max.

to bottom of solid soffit

77"

(196 cm)

47 1/2" (120.7 cm) to

47 3/4" (121.3 cm)

39"

(99.1 cm)

437/8"

111.4 cm)

44"

(111.8 cm)

19 1/4" (48.9 cm)

51 3/8"

(130.5 c

90˚

110˚

130˚

90˚

110˚

130˚

 

 

6"

 

 

(15.2 cm)

 

 

TOP GRILL CLEARANCE

 

 

1/2"

 

 

(1.3 cm)

 

1"

 

6"

(2.54 cm)

6"

(15.2 cm)

 

(15.2 cm)

24"

(60.96 cm) min.

The location must permit both doors to open to a minimum of 90°. Allow 4 1/2" (11.4 cm) minimum space between the side of the refrigerator and a corner wall.

NOTE: More clearance may be required if you are using overlay panels or custom handles.

To avoid tipping during use, the solid soffit must be within 1" (2.5 cm) maximum above the refrigerator. If the solid soffit is higher than 1" (2.5 cm) or one is not available, then the refrigerator must be braced.

If the anti-tip boards are needed, they must be attached to the rear wall studs 80" to 90" (203 to 229 cm) above the floor.

Note: A clearance of 1/2" (1.3 cm) must be maintained above the top grille in order for the top grille to be removed.

A grounded 3 prong electrical outlet should be placed within 4" (10.2 cm) of the right side cabinets or end panel. The water shutoff should be located in the base cabinet on either side of the refrigerator or some other easily accessible area. If the water shutoff valve is not in the cabinets, the plumbing for the water line can come through the floor or the back wall.

47" (119 cm)

25 1/8"

(64 cm)

1.800.735.4328 THERMADOR.COM

275

 

Page 16
Image 16
Thermador KBUIT4255E manual THERMADOR.COM 275