Thermador KBUDT4275E, KBUIT4275E, KBUIT4855E Electrical Requirements, Recommended Grounding Method

Models: 2327570A KBUDT4255E KBUDT4855E KBUDT4265E KBUDT4875E KBUIT4875E KBUIT4265E KBUIT4865E KBUDT4865E KBUIT4255E, KBUIT4255E, KBUDT4255E KBUIT4265E, KBUDT4265E KBUIT4275E, KBUDT4275E KBUIT4855E, KBUDT4855E KBUIT4865E, KBUDT4865E KBUIT4875E, KBUDT4875E KBUDT4275E KBUIT4855E KBUIT4275E

1 68
Download 68 pages 60.92 Kb
Page 15
Image 15

If the anti-tip boards are needed, they must be attached to the rear wall studs 80" to 90" (203 to 229 cm) above the floor. See “Install Anti-Tip Boards” for more information.

NOTE: A clearance of ¹⁄₂" (1.3 cm) must be maintained above the top grille in order for the top grille to be removed.

¹⁄₂"

(1.3 cm)

A grounded 3 prong electrical outlet should be placed within 4" (10.2 cm) of the right side cabinets or end panel. See “Electrical Requirements” for additional information.

The water shutoff should be located in the base cabinet on either side of the refrigerator or some other easily accessible area. If the water shutoff valve is not in the cabinets, the plumbing for the water line can come through the floor or the back wall. See “Water Supply Requirements” for more information.

 

80" - 90"

 

 

(203-229 cm)

4"

 

 

 

 

(10.2 cm)

83¹⁄₂" (212.1 cm) min.

 

84³⁄₄" (215 cm) max.

 

to bottom of solid soffit

 

 

 

77"

 

 

(196 cm)

 

A

 

 

Width

 

 

(see chart following)

 

 

 

6"

 

 

(15.2 cm)

 

1"

 

6"

(2.54 cm)

6"

(15.2 cm)

(15.2 cm)

 

24"

 

 

(60.96 cm) min.

 

Model Width A (as shown above)

4241¹⁄₂" (105.4 cm) to 41³⁄₄" (106.1 cm)

4847¹⁄₂" (120.7 cm) to 47³⁄₄" (121.3 cm)

Electrical Requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Before you move your refrigerator into its final location, it is important to make sure you have the proper electrical connection.

Recommended Grounding Method

A 115 Volt, 60 Hz., AC only, 15- or 20-amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your refrigerator be provided. Use an outlet that cannot be turned off by a switch. Do not use an extension cord.

IMPORTANT: If this product is connected to a GFCI (Ground Fault Circuit Interrupter) protected outlet, nuisance tripping of the power supply may occur, resulting in loss of cooling. Food quality and flavor may be affected. If nuisance tripping has occurred, and if the condition of the food appears poor, dispose of it.

NOTE: Before performing any type of installation, cleaning, or removing a light bulb, remove the top grille and turn the master power switch to OFF or disconnect power at the circuit breaker box.

When you are finished, turn ON the master power switch or reconnect power at the circuit breaker box. Then reset the control to the desired setting.

15

Page 15
Image 15
Thermador KBUDT4275E, KBUIT4275E Electrical Requirements, Recommended Grounding Method, Model Width a as shown above