PRO hARMONY® RANGES PLANNiNG iNFORMATiON
MODEL OPTiONS
There are three sizes of Thermador Pro Harmony Ranges to choose
iNSTALLATiON cONSiDERATiONS
The information in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Pro Harmony Range, be sure to verify the cutout dimensions and electrical/gas connections. Also, always consult with the installation manual packed with the product for complete details before installing.
ELEcTRicAL AND GAS SPEciFicATiONS
Be sure your appliance is properly installed and grounded by a qualified technician. Installation, electrical and gas connections, and grounding must comply with all applicable local codes.
GAS REQuiREMENTS AND hOOkuP
Verify that the type of gas being used at the installation site matches the type of gas used by the appliance.
If an LP kit is utilized (PALPKITHC), conversion from natural gas to propane must be done by qualified service personnel only. Please refer to the LP Conversion Instructions packed with product for further information.
A manual gas shutoff valve must be installed external to the appliance, in a location accessible from the front, for the purpose of shutting off the gas supply. The supply line must not interfere with the back of the unit.
NATuRAL GAS REQuiREMENTS:
Inlet Connection: 3/4" NPT external, 1/2" NPT internal (Minimum 3/4" diam. flex line.)
Supply Pressure: 6" min. to 14" max. water column. (14.9 mb to 34.9 mb)
Manifold Pressure: 5" water column (12.5 mb)
PROPANE GAS REQuiREMENTS:
Inlet Connection: 3/4" NPT external, 1/2" NPT internal (Minimum 3/4" diam. flex line.)
Supply Pressure: 11" min. to 14" max. water column. (27.4 mb to 34.9 mb)
Manifold Pressure: 10" water column (24.9 mb)
DuAL-FuEL:
Thermador Pro Harmony
MODEL | REQuiRED ciRcuiT BREAkER |
| 240/208V AC, 60 Hz |
|
|
PRD304GHu | 35 Amp |
|
|
PRD364GDHu | 35 Amp |
|
|
PRD366GHu | 35 Amp |
|
|
PRD486GDHu | 50 Amp |
|
|
ALL-GAS:
Thermador Pro Harmony
MODEL | REQuiRED ciRcuiT BREAkER |
| 120V AC, 60 Hz |
|
|
PRG304GH | 15 Amp |
|
|
PRL304GH | 15 Amp |
|
|
PRG366GH | 15 Amp |
|
|
PRL366GH | 15 Amp |
|
|
PRG364GDH | 20 Amp |
|
|
PRL364GDH | 20 Amp |
|
|
important:
The cord supplied with gas ranges having an electric griddle requires a NEMA
PLUG
NEMA
RECEPTACLE
44