Thermador PRD486GDHU manual Min

Models: PRD486GDHU

1 20
Download 20 pages 3.9 Kb
Page 18
Image 18

iNSTALLATiON OPTiONS

Thermador Pro Harmony® Ranges feature a bold, professional design and a compact, 24-inch depth profile that creates a seamless look within standard cabinetry. These ranges can be installed in a wall or island installation.

BAckGuARD

36-inch Thermador Pro Harmony Ranges require an accessory backguard. Choices include a 9-inch low backguard or a 22-inch high backguard with shelf.

Either backguard must be attached before sliding the range into the final installed position. An island trim is included for covering the backguard mounting flanges for island installations, where there is a minimum of 12" of horizontal clearance behind the island trim.

cAuTiON: To avoid possible burn or fire hazard, a backguard designed specifically for this range must be installed whenever the range is used.

NATuRAL GAS OR LP

Thermador All-Gas Pro Harmony Ranges are shipped by the factory to operate on natural gas or LP. Be sure to order the correct fuel-type and verify the type of gas being used at the installation site matches the type of gas used by the appliance.

iMPORTANT

We strongly recommend that a Thermador Professional Wall or Island Hood or Custom Insert be installed with all Thermador Pro Harmony Ranges. Downdraft ventilation should not be used. Do not install a microwave-hood combination above the cooktop, as these types of units do not provide

the proper ventilation and are not suitable for use with Thermador Pro Harmony Ranges. Refer to the Ventilation section or www.Thermador.com for a complete selection of Professional ventilation options, blowers, and accessories.

Due to the high surface temperature output of the Pro Harmony Ranges, the HPWB Professional Series Wall Hoods or the Professional Series Custom Inserts are recommended ventilation solutions for these ranges. The PH Professional Series Wall Hoods are also a viable option, however the 27" depth of the PH Series may not be suitable to all applications.

PRO hARMONY® RANGES 36-iNch GAS

Models: PRG366Gh / PRL366Gh

36-INCH CuTOuT AND RANGE DIMENSIONS

 

 

 

 

*min. 30"- 40"

 

36"

 

 

24"

 

 

 

 

 

8

/8"

 

**min. 10"

 

 

 

 

 

1

 

 

19

/16"

3

3

/16"

 

13

 

 

Gas and Electric connections

*30" minimum clearance above cooking surface to non-combustible surface. Minimum clearance above cooking surface to combustible surface is 40".

**10" minimum clearance from cooking surface to combustible side walls.

Note: Most hoods contain combustible components that must be considered when planning the installation.

measurement in inches

35

15

/16"

 

 

35

7

 

 

/8"-

1

36

3

27

/4"

/4"

27

5

 

 

/8"

 

 

24

3

 

 

/4"

 

 

23"

 

 

 

44

7

 

 

/8"

 

measurement in inches

PRO hARMONY RANGES

1.800.735.4328 THERMADOR.COM

57

 

Page 18
Image 18
Thermador PRD486GDHU manual Min