Thermador VTN420B installation instructions Tab

Models: VTN420B

1 17
Download 17 pages 358 b
Page 10
Image 10

BEFORE INSTALLING HOOD

Discharge Direction: The hood is shipped ready for horizontal discharge. To change to vertical discharge move plate to the rear side and ventilator (if supplied) to the top side.

The plate and ventilator are held in place by four nuts each, see also Figures 3 and ,at page 9, Figure A and Figure B.

Read also paragraph “Integral Ventilator Installation” at pages 14-15 for further informations. Note: If an integral ventilator is already supplied (HSB series hoods only), remove it to allow installation of hood to the wall/cabinet.

Assembly of the Transition: The transition supplied with the hood mounts to the top of the hood, Figure 4.

1.Fold outwards all six Tabs (HS and HSB series only).

2.Align mounting holes at base of transition with mounting holes on 1/2” flange located at the top of the hood.

3.Fasten transition to hood using 6 (4 mm x 9.5 mm) screws (included with hood).

4.Duct tape connection between transition and hood.

5.Remove tape holding damper

Plate

Figure 3

Transition

Top outlet

plate fixing point

Tab

Figure 4

Page 10

Page 10
Image 10
Thermador VTN420B installation instructions Tab