Thermo Products OL11-105 Riello Burner Application Chart, I. Heat Exchanger Cleaning Instructions

Models: OC5-85 OC2-56 OL11-105 OL2-56 OL20-151 OL39-320 OH11-105 OH5-85 OT11-105 OL33-200 OH3-72 OL37-250 OL5-85 OT16-125 OL16-125 OH16-125 OH2-56 OT5-85

1 32
Download 32 pages 24.61 Kb
Page 15
Image 15
RIELLO BURNER APPLICATION CHART

All installations and services must be performed by qualified service personnel.

RIELLO BURNER APPLICATION CHART

The optional F3 and F5 Riello flame retention oil burners have been UL listed (UL File #MP3252) for application on the following Thermo Pride oil fired furnaces.

MODEL

OH3

OC5, OL5,

OL11, OH11,

OL16, OH16,

OL20

PART

OH5, OT5

OT11

OT16

 

 

MTG. PLATE

TOP-25752

35750

35750

35750

35750

PART NO.

BTM-35733

 

 

 

 

 

 

 

 

 

 

 

MTG. PLATE

 

 

 

 

 

GASKET

330090

330088

330088

330088

330088

PART NO.

 

 

 

 

 

 

 

 

 

 

 

**NOZZLE

.50-60A

.60-60A*

.75-60A*

.90-60A*

1.10-60A*

SIZE

 

 

 

 

 

 

 

 

 

 

 

NOZZLE

380393

380394

380395

380396

380397

PART NO.

 

 

 

 

 

 

OIL PUMP

170 PSI

145 PSI

145PSI

145 PSI

150PSI

PRESSURE

 

 

 

 

 

 

 

 

 

 

 

BURNER

F3

F3

F5

F5

F5

 

 

 

 

 

 

BURNER

380215

380215

380216

380216

380216

PART NO.

 

 

 

 

 

 

 

 

 

 

 

*A refers to hollow pattern nozzle

**NOTE: The reason the Riello burner nozzle sizes are smaller than the standard Thermo Pride burner nozzles is that pre-set pump pressures are higher, therefore achieving the same firing rate with a smaller nozzle.

For more specific burner information, specifications or service information, reference the training manual enclosed

with each Riello burner or contact:Riello Corporation of America, 5 Pond Park Road

Hingham, Massachusetts 02043

(617)749-8292

I. HEAT EXCHANGER CLEANING INSTRUCTIONS:

?WARNING: THE HEAT EXCHANGER MUST BE CLEANED BY A QUALIFIED SERVICE PERSON.

It is important to inspect and clean the heat exchanger once a year, or as necessary, to remove any build-up of soot. A layer of soot on the inside of the heat exchanger will act as an insulator and reduce heat transfer, resulting in less efficiency.

To clean the heat exchanger, first turn off all power to the unit. Next, remove the access panel (see below and beginning of following page) immediately above the burner (on the horizontal furnace, it will be located to the side of the burner) to gain entry to the clean-out covers, refer to figure 15. This panel is identified with a label. Remove clean-out covers, the vent connector pipe to the chimney, the burner, and the burner mounting plates. When removing the clean-out covers, special care must be taken not to damage the gaskets. Should the gaskets separate, crack, break, or be unsuitable for reuse, the gasket must be replaced before reattaching the clean-out covers.

11

Page 15
Image 15
Thermo Products OL11-105, OT5-85, OH2-56, OH16-125 Riello Burner Application Chart, I. Heat Exchanger Cleaning Instructions