Optional Matching Transformer Mounting
[CAUTION]
THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN
THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE
QUALIFIED TO DO SO. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL.
The
1.Set the power switch to OFF and unplug the AC cord form a wall outlet.
2.Remove the case by loosening six side panel screws (three each on each side) and two rear panel screws.
3.Install sleeves (supplied with the transformer) by tightening screws from the other side of a chassis, and mount the transformer to the sleeves using screws. See Fig. 1.The input transformer must be located on the left and the output transformer on the right.
4. When mounting the input transformer, detach | connector from | |||
the detached connector to connector at the transformer side, and then connect | ||||
connector from the transformer to CN104. |
| connector from | ||
When mounting the output transformer, | detach | |||
reconnect the detached connector to | connector at the transformer side, and then | |||
connect | connector from the transformer to CN103. |
| ||
See Fig.1. |
|
|
|
|
|
| Fig.1 |
5. Fit the case in place. |
|
|
Transformer Specifications |
|
|
Model | ||
Frequency response | 30Hz ~ 20kHz | 30Hz ~ 20kHz |
| (at ±0.15dB) | (at ±0.15dB) |
Constant loss | Within 1.5dB(at 1kHz) | Within 1.5dB(at 1kHz) |
Distortion | Less than 0.2%(50Hz/5dB) | Less than 0.2%(50Hz/5dB) |
0dB = 0.775V RMS
Specifications are subject to change without notice.