TOA Electronics HB-1 operating instructions Matching Transformer Installation

Models: HB-1

1 12
Download 12 pages 46.84 Kb
Page 9
Image 9
7. MATCHING TRANSFORMER INSTALLATION

7. MATCHING TRANSFORMER INSTALLATION

An optional MT-S0601 matching transformer can be installed in the HB-1 speaker.

Enclosure cover mounting screw (13 pieces)

1

Cover

Disconnect by widening the lock tab

3

MT-S0601

Red White

4

2

Connection tab

MT-S0601

Transformer mounting screw

Step 1. Remove the 13 enclosure cover fixing screws to detach the cover.

Step 2. Remove the two screws located inside an enclosure. Using the removed two screws, mount the MT- S0601 transformer so that its connection tab is facing the front of the enclosure.

Step 3. Detach the woofer's lead wire junction connector, and connect it to the MT-S0601's connector.

Step 4. Connect the speaker input cable to the desired impedance tap.

Step 5. Replace the enclosure cover.

Step 6. Choose an appropriate impedance indication

 

label from those supplied with the MT-S0601,

Nameplate

and affix it over the HB-1's nameplate to indicate

6

the selected impedance.

Indication label

Impedance label sheet (supplied with MT-S0601)